A study of BlockBuster laryngeal mask airway versus Fastrach/Intubating laryngeal mask airway as a conduit for blind oro-tracheal intubation: A prospective randomized controlled study

Author:

Pathak Ruchi1,Modi Komal2ORCID,Kanchanaa S. P.

Affiliation:

1. G

2. Government Medical College and S.S.G. Hospital, Baroda, Gujarat, India

Abstract

A Laryngeal Mask Airway (LMA) has two parts, a simple breathing tube and a mask. The mask at the laryngeal end of the tube aligns against the glottis and provides better channel of ventilation than the face mask. There have been modifications in the basic design of the LMA to incorporate gastric drainage channel and some devices are also equipped with a channel for intubation to secure airway by guiding endotracheal tube (ETT) through it. In this study we evaluated the performance of two LMA devices that can aid in rescue ventilation and are also equipped with a channel for intubation namely the BlockBuster LMA(2012) and the Fastrach/ Intubating LMA(1997) for blind oro-tracheal intubation in terms of First attempt success rate and Over-all success rate of intubation. A hundred consenting patients of age group 18-60 years and ASA status I or II, were randomly allocated into two groups Group BB (BlockBuster LMA) and Group FT (Fastrach LMA) with 50 patients each. Standard anesthesia technique was used for both groups. After insertion of airway device, cuff was inflated and ventilation was attempted (maximum 2 attempts). Once ventilation was achieved, ETT of appropriate size was inserted through LMA (maximum 2 attempts). The correct placement of ETT was confirmed by capnography. Data was collected for number of attempts of tracheal intubation, time taken for intubation and complications. First attempt success rate of intubation was more in Blockbuster LMA than Fastrach LMA. Over-all success rate of Intubation was 100% for both devices. Time taken for intubation and incidence of post-operative sore throat was less in BlockBuster LMA than Fastrach LMA(p-value<0.05). Blockbuster LMA is better conduit for oro-tracheal intubation than Fastrach LMA in terms of higher first attempt success rate, lesser time taken for intubation and lesser post-operative complications.

Publisher

IP Innovative Publication Pvt Ltd

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3