Transvaginal Ultrasonography and Saline Infusion Sonography Compared to Hysteroscopy for Diagnosis of Intracavity Lesion: A 4-Year Experience in Suburban Referral Hospital

Author:

Abstract

Objective: To evaluate the accuracy of transvaginal ultrasonography (TVS) and saline infusion sonography (SIS) in use for the diagnosis of endometrial polyps and submucous myoma compared to hysteroscopy. Histopathology was considered as the gold standard for final diagnosis. Materials and Methods: The present retrospective study was conducted at Bhumibol Adulyadej Hospital, Bangkok, Thailand between January 2014 and December 2017. Medical records of 150 patients who attended for hysteroscopy and histopathological diagnosis were reviewed. The accuracy of TVS and SIS for the diagnosis of endometrial polyps and submucous myoma were determined. Results: Out of 150 enrolled cases, endometrial polyp was the most frequent hysteroscopic finding in participants of the present study (92/150). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of TVS, SIS, and hysteroscopy compared to pathologic reports for detection endometrial polyps were 71.7% versus 93.5% versus 97.8%, 38.5% versus 52.2% versus 68.2%, 80.5% versus 88.7% versus 92.8%, 27.8% versus 66.7% versus 88.2%, and 64.4% versus 85.2% versus 92.1%, respectively. The sensitivity, specificity, PPV, NPV, and accuracy of TVS, SIS, and hysteroscopy for detection of submucous myoma were 81.6% versus 92.1% versus 94.7%, 66.7% versus 86.9% versus 100%, 77.5% versus 92.1% versus 100%, 72.0% versus 86.9% versus 90.9%, and 75.4% versus 90.2% versus 96.6%, respectively. The kappa value from TVS, SIS, and hysteroscopy when the histopathologic reports were overall intrauterine abnormalities, endometrial polyps and submucous myoma were 0.45/0.43/0.72, 0.77/0.76/0.89, and 0.92/0.92/1.00, respectively. Conclusion: Sensitivity, specificity, PPV, NPV, accuracy, and kappa value of SIS for detecting endometrial polyps and submucous myoma were better than TVS. Keywords: Ultrasonography, Saline infusion sonography, Hysteroscopy, Accuracy

Publisher

Medical Association of Thailand

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3