Affiliation:
1. Microsoft Research, India
2. Sankara Eye Hospital, India
Abstract
Keratoconus is a severe eye disease affecting the cornea (the clear, dome-shaped outer surface of the eye), causing it to become thin and develop a conical bulge. The diagnosis of keratoconus requires sophisticated ophthalmic devices which are non-portable and very expensive. This makes early detection of keratoconus inaccessible to large populations in low-and middle-income countries, making it a leading cause for partial/complete blindness among such populations. We propose SmartKC, a low-cost, smartphone-based keratoconus diagnosis system comprising of a 3D-printed placido's disc attachment, an LED light strip, and an intelligent smartphone app to capture the reflection of the placido rings on the cornea. An image processing pipeline analyzes the corneal image and uses the smartphone's camera parameters, the placido rings' 3D location, the pixel location of the reflected placido rings and the setup's working distance to construct the corneal surface, via the Arc-Step method and Zernike polynomials based surface fitting. In a clinical study with 101 distinct eyes, we found that SmartKC achieves a sensitivity of 87.8% and a specificity of 80.4%. Moreover, the quantitative curvature estimates (sim-K) strongly correlate with a gold-standard medical device (Pearson correlation coefficient = 0.77). Our results indicate that SmartKC has the potential to be used as a keratoconus screening tool under real-world medical settings.
Publisher
Association for Computing Machinery (ACM)
Subject
Computer Networks and Communications,Hardware and Architecture,Human-Computer Interaction
Reference48 articles.
1. Behnam Askarian , Jo Woon Chong , Fatemehsadat Tabei, and Amin Askarian. 2018 . An affordable and easy-to-use diagnostic method for keratoconus detection using a smartphone. In Medical Imaging 2018: Computer-Aided Diagnosis, Kensaku Mori and Nicholas Petrick (Eds.). SPIE. https://doi.org/10.1117/12.2293765 Behnam Askarian, Jo Woon Chong, Fatemehsadat Tabei, and Amin Askarian. 2018. An affordable and easy-to-use diagnostic method for keratoconus detection using a smartphone. In Medical Imaging 2018: Computer-Aided Diagnosis, Kensaku Mori and Nicholas Petrick (Eds.). SPIE. https://doi.org/10.1117/12.2293765
2. B. Askarian F. Tabei G. A. Tipton and J. W. Chong. 2019. Novel Keratoconus Detection Method Using Smartphone. In 2019 IEEE Healthcare Innovations and Point of Care Technologies (HI-POCT). 60--62. https://doi.org/10.1109/HI-POCT45284.2019.8962648 B. Askarian F. Tabei G. A. Tipton and J. W. Chong. 2019. Novel Keratoconus Detection Method Using Smartphone. In 2019 IEEE Healthcare Innovations and Point of Care Technologies (HI-POCT). 60--62. https://doi.org/10.1109/HI-POCT45284.2019.8962648
3. PAR Corneal Topography System (PAR CTS): The Clinical Application of Close-Range Photogrammetry
4. An introduction to understanding elevation-based topography: how elevation data are displayed - a review
5. Manuel Campos-García , Victor Armengol-Cruz , and Arturo Osorio-Infante . 2019. Evaluating the anterior corneal surface using an improved null-screen system. OSA Continuum 2 (03 2019 ), 736. https://doi.org/10.1364/OSAC.2.000736 Manuel Campos-García, Victor Armengol-Cruz, and Arturo Osorio-Infante. 2019. Evaluating the anterior corneal surface using an improved null-screen system. OSA Continuum 2 (03 2019), 736. https://doi.org/10.1364/OSAC.2.000736
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献