Author:
Levey A S,Greene T,Schluchter M D,Cleary P A,Teschan P E,Lorenz R A,Molitch M E,Mitch W E,Siebert C,Hall P M
Abstract
To assess the utility and precision of GFR measurements in multicenter trials, the test performance and variability of GFR were analyzed in 2,250 patients enrolled in 44 clinical centers participating in either the Modification of Diet in Renal Disease (MDRD) Study or the Diabetes Control and Complications Trial (DCCT). GRF was measured as the renal clearance of [125I]iothalamate after an sc injection without epinephrine. The studies used similar protocols for obtaining blood and urine, training clinical center staff, and processing specimens in central laboratories. The performance of GFR measurements, assessed from adherence to protocol and quality control analyses, was excellent. The variability among the four clearance periods (intratest coefficient of variation [CV]) was acceptable; the median intratest CV for GFR was 9.4% in the MDRD Study and 11.7% in the DCCT. The pattern of decline in serum counts was better approximated by an exponential rather than a linear relationship. The cause of the intratest variability in GFR measurements was explored by univariate and multivariate analysis. The intratest CV was highest at the extremes of GFR. Among patients with a high GFR (> 90 mL/min per 1.73 m2), most of whom were participants in the DCCT, the higher intratest GFR was due, in part, to a systematic decline in GFR during the test. Among patients with a very low GFR (< 13 mL/min per 1.73 m2), technical difficulties in urine collections contributed substantially to the higher intratest CV. Other patient characteristics, including age, gender, weight, serum glucose, renal diagnosis, and use of diuretics, were not strongly correlated with the intratest CV. The precision of GFR measurements was assessed from the variability from measurement to measurement (interest CV). Among MDRD Study subjects, in whom two measurements of GFR were performed over a 3-month interval, the median interest CV was relatively low (6.3%) and was only weakly related to the intratest CV. Thus, GFR measurements are reasonably precise, even if the intratest CV is high. Given the relatively high intratest CV that is characteristic of GFR measurements, the estimate of GFR in an individual is more precise if multiple clearance periods, rather than a single period, are included. Similarly, the estimate of mean GFR for a population is also more precise if multiple clearance periods are included. In conclusion, by the use of standardized methods, an acceptable precision of GFR results can be obtained in multicenter trials. The same methods can be applied in clinical practice.(ABSTRACT TRUNCATED AT 400 WORDS)
Publisher
American Society of Nephrology (ASN)
Subject
Nephrology,General Medicine
Cited by
122 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献