Glomerular filtration rate measurements in clinical trials. Modification of Diet in Renal Disease Study Group and the Diabetes Control and Complications Trial Research Group.

Author:

Levey A S,Greene T,Schluchter M D,Cleary P A,Teschan P E,Lorenz R A,Molitch M E,Mitch W E,Siebert C,Hall P M

Abstract

To assess the utility and precision of GFR measurements in multicenter trials, the test performance and variability of GFR were analyzed in 2,250 patients enrolled in 44 clinical centers participating in either the Modification of Diet in Renal Disease (MDRD) Study or the Diabetes Control and Complications Trial (DCCT). GRF was measured as the renal clearance of [125I]iothalamate after an sc injection without epinephrine. The studies used similar protocols for obtaining blood and urine, training clinical center staff, and processing specimens in central laboratories. The performance of GFR measurements, assessed from adherence to protocol and quality control analyses, was excellent. The variability among the four clearance periods (intratest coefficient of variation [CV]) was acceptable; the median intratest CV for GFR was 9.4% in the MDRD Study and 11.7% in the DCCT. The pattern of decline in serum counts was better approximated by an exponential rather than a linear relationship. The cause of the intratest variability in GFR measurements was explored by univariate and multivariate analysis. The intratest CV was highest at the extremes of GFR. Among patients with a high GFR (> 90 mL/min per 1.73 m2), most of whom were participants in the DCCT, the higher intratest GFR was due, in part, to a systematic decline in GFR during the test. Among patients with a very low GFR (< 13 mL/min per 1.73 m2), technical difficulties in urine collections contributed substantially to the higher intratest CV. Other patient characteristics, including age, gender, weight, serum glucose, renal diagnosis, and use of diuretics, were not strongly correlated with the intratest CV. The precision of GFR measurements was assessed from the variability from measurement to measurement (interest CV). Among MDRD Study subjects, in whom two measurements of GFR were performed over a 3-month interval, the median interest CV was relatively low (6.3%) and was only weakly related to the intratest CV. Thus, GFR measurements are reasonably precise, even if the intratest CV is high. Given the relatively high intratest CV that is characteristic of GFR measurements, the estimate of GFR in an individual is more precise if multiple clearance periods, rather than a single period, are included. Similarly, the estimate of mean GFR for a population is also more precise if multiple clearance periods are included. In conclusion, by the use of standardized methods, an acceptable precision of GFR results can be obtained in multicenter trials. The same methods can be applied in clinical practice.(ABSTRACT TRUNCATED AT 400 WORDS)

Publisher

American Society of Nephrology (ASN)

Subject

Nephrology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3