Clinical Results of Cataract Surgery Using the ARTIS ® PL E Intraocular Lens

Author:

Park Ella Seo Yeon,Chung Byung Hoon,Jun Ikhyun,Kim Tae-im,Seo Kyoung Yul,Kim Eung Kweon

Abstract

Purpose: To compare the clinical outcomes of cataract surgery using the ARTIS ® PL E (Cristalens Industrie, Lannion, France) intraocular lens (IOL) and conventional Tecnis ® ZCB00 (Johnson & Johnson Vision, Santa Ana, CA, USA) IOL.Methods: This retrospective study examined patients who underwent in-the-bag implantation of either an ARTIS ® PL E (33 eyes, group A) or Tecnis ® ZCB00 (45 eyes, group B) IOL after phacoemulsification performed by a single surgeon. Best-corrected visual acuity (BCVA), spherical equivalent, and higher-order aberrations (HOA) were measured 1 and 3 months after cataract surgery.Results: Preoperative BCVA did not differ significantly in groups A and B. Postoperative BCVA at 1 and 3 months improved significantly (<i>p</i> < 0.001) in both groups compared to preoperative baseline BCVA. At 1 and 3 months postoperatively, total HOA, spherical aberration, and coma were significantly lower compared to the preoperative baseline HOA (<i>p</i> < 0.05) in both groups. However, there were no significant differences in the trefoil values 1 and 3 months postoperatively compared to the preoperative baseline in both groups. The absolute refractive error 3 months postoperatively was 0.27 ± 0.20 (group A) and 0.28 ± 0.20 (group B), both within ± 0.50 diopters of the targeted goal diopter; there were no significant differences in the accuracy or predictability of the IOL power calculation in both groups (<i>p</i> = 0.390, <i>p</i> = 0.959). The absolute refractive error 1 and 3 months postoperatively did not differ significantly; there were no significant differences in the stability of both IOLs (<i>p</i> = 0.482, <i>p</i> = 0.372).Conclusions: Conventional cataract surgery using the ARTIS ® PL E IOL significantly increased the BCVA, while obtaining comparable clinical results to the verified Tecnis ® ZCB00 IOL in postoperative visual acuity and HOA.

Publisher

Korean Ophthalmological Society

Subject

Ophthalmology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3