Interim Phase II Results Using Panitumumab-IRDye800CW during Transoral Robotic Surgery in Patients with Oropharyngeal Cancer

Author:

Stone Logan D.1ORCID,Kasten Benjamin B.1ORCID,Rao Shilpa1ORCID,Gonzalez Manuel. L.2ORCID,Stevens Todd M.3ORCID,Lin Diana4ORCID,Carroll William1ORCID,Greene Benjamin1ORCID,Moore Lindsay S.1ORCID,Fuson Andrew1ORCID,James Sherin1ORCID,Hartman Yolanda E.1ORCID,McCammon Susan1ORCID,Panuganti Bharat1ORCID,Nabell Lisle M.15ORCID,Li Yufeng6ORCID,Li Mei6ORCID,Bailey Luke1ORCID,Rosenthal Eben L.7ORCID,Jeyarajan Harishanker1ORCID,Thomas Carissa M.1ORCID,Warram Jason M.1ORCID

Affiliation:

1. Department of Otolaryngology, University of Alabama at Birmingham, Birmingham, Alabama. 1

2. Department of Pathology, University of Miami, Miami, Florida. 2

3. Department of Pathology, University of Kansas Medical Center, Kansas City, Kansas. 3

4. Department of Pathology, University of Alabama at Birmingham, Birmingham, Alabama. 4

5. Division of Hematology/Oncology, Department of Medicine, University of Alabama at Birmingham, Birmingham, Alabama. 5

6. Department of Medicine, University of Alabama at Birmingham, Birmingham, Alabama. 6

7. Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee. 7

Abstract

Abstract Purpose: The incidence of oropharyngeal squamous cell carcinoma (OPSCC) has continually increased during the past several decades. Using transoral robotic surgery (TORS) significantly improves functional outcomes relative to open surgery for OPSCC. However, TORS limits tactile feedback, which is often the most important element of cancer surgery. Fluorescence-guided surgery (FGS) strategies to aid surgeon assessment of malignancy for resection are in various phases of clinical research but exhibit the greatest potential impact for improving patient care when the surgeon receives limited tactile feedback, such as during TORS. Here, we assessed the feasibility of intraoperative fluorescence imaging using panitumumab-IRDye800CW (PAN800) during TORS in patients with OPSCC. Patients and Methods: Twelve consecutive patients with OPSCC were enrolled as part of a nonrandomized, prospective, phase II FGS clinical trial using PAN800. TORS was performed with an integrated robot camera for surgeon assessment of fluorescence. Intraoperative and ex vivo fluorescence signals in tumors and normal tissue were quantified and correlated with histopathology. Results: Intraoperative robot fluorescence views delineated OPSCC from normal tissue throughout the TORS procedure (10.7 mean tumor-to-background ratio), including in tumors with low expression of the molecular target. Tumor-specific fluorescence was consistent with surgeon-defined tumor borders requiring resection. Intraoperative robot fluorescence imaging revealed an OPSCC fragment initially overlooked during TORS based on brightfield views, further substantiating the clinical benefit of this FGS approach. Conclusions: The results from this patient with OPSCC cohort support further clinical assessment of FGS during TORS to aid resection of solid tumors.

Funder

National Cancer Institute

Publisher

American Association for Cancer Research (AACR)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3