One-way Valve Bottle Contamination Rates in the Immediate Post–functional Endoscopic Sinus Surgery Period

Author:

Kofonow Jennifer M.1,Bhuskute Aditi2,Doghramji Laurel1,Palmer James N.1,Cohen Noam A.13,Chiu Alexander G.2

Affiliation:

1. Department of Otorhinolaryngology, University of Pennsylvania, Philadelphia, Pennsylvania

2. Department of Surgery, University of Arizona, Tuscon, Arizona

3. Philadelphia Veterans Affairs Medical Center, Philadelphia, Pennsylvania

Abstract

Background Sinonasal saline irrigation has become an accepted practice in the immediate postoperative management of functional endoscopic sinus surgery (FESS) patients. Recent studies have found that valveless delivery systems of sinonasal irrigation are colonized with bacteria. An alternative delivery system uses a one-way valve to reduce saline backflow and may limit bottle contamination. Our sole objective was to determine whether this system in post-FESS patients eliminates microbial bottle contamination. Methods Eight patients undergoing FESS were given one-way valve irrigation bottles to use immediately after surgery. Bottles were collected after 1 week of use and another set of bottles after an additional week. Endoscopic-directed cultures of the middle meatus were performed at the time of surgery. Returned used bottles were swabbed for bacteria and the valve system of the bottle was analyzed under scanning electron microscopy (SEM) for the presence of bacteria. Results All sinus swabs collected at the time of surgery grew bacteria with Staphylococcus sp. present in all samples. After the 1st week of use, 5/8 bottles grew bacterial cultures and showed bacterial presence on the valves by SEM. After the 2nd week, 4/5 bottles had positive culture results and also showed bacterial presence on the valves by SEM. Conclusion Despite commercial claims that the use of valves and limit of backflow into the bottle will eliminate contamination, our study showed that one-way valve delivery systems become contaminated with bacteria after 1 week of use. We also showed that the bottle valves themselves harbor bacteria after 1 week of use.

Publisher

SAGE Publications

Subject

General Medicine,Otorhinolaryngology,Immunology and Allergy

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3