Algorithm to assess neutron HP(10) with estimation of uncertainties using Alnor albedo dosemeters: application in Brazilian nuclear power plants

Author:

Ferreira Max da Silva,Maurício Cláudia Lúcia de Pinho,Silva Everton Rodrigues

Abstract

The Instituto de Radioproteção e Dosimetria (IRD) is implementing an automatic neutron individual monitoring system, which uses albedo dosemeters from the Alnor manufacturer. For practical purposes, the occupational neutron fields have been divided into four application areas, named N1, N2, N3 and N4, as recommended in the German standard DIN 6802-4. For each area, specific Workplace Correction Factor (WCF), as a function of the ratio between photon dose responses measured in the incident and albedo component of the albedo dosemeter (Di/Da), must be used. This study proposes an algorithm for evaluating the photons and neutrons HP(10) values for the Alnor albedo system. It uses WCF × Di/Da curves previously defined by the authors, using MCNPX code simulations of the neutron dosemeter response for several occupational neutron fields. The methodology for calculating all uncertainties involved in the photon and neutron HP(10) assessment is also shown. Before the routine use of this system at IRD, several tests and calibrations are being carried out. This manuscript presents a case study carried out at the Angra I and Angra II power plants in 14 different fields (N1 application area). The results of the Alnor system are compared with those from the albedo system currently in routine use at the IRD. The average value of the ratio between the measurements with the Alnor system and the IRD system was 0.97 for photon HP(10), and 0.84 for neutron HP(10). Considering an expanded uncertainty to 95% confidence level, all results agree with each other.

Publisher

Sociedade Brasilieira de Protecao Radiologica - SBPR

Subject

General Medicine

Reference7 articles.

1. MARTINS, M. M.; MAURICIO, C. L. P.; FONSECA, E. S.; DA SILVA, A. X. Brazilian two-component TLD albedo neutron individual monitoring system, Radiat. Meas., v. 45, pp. 1509 1512, 2010.

2. PIESCH, E.; BURGKHARDT, B. Erprobung eines Albedoneutronendosimetriesystems: TLD Kalibrier- und Meßverfahren, Neutronenkalibrierung, dosimetrische Eigenschaften, Routineanwendung, KfK 4303, Kernforschungszentrum Karlsruhe, Hauptabteilung Sicherheit, 1988.

3. PIESCH, E., BURGKHARDT, B.; UGI S. The Karlsruhe TLD Service for Albedo Neutron Dosimetry. In: Oberhofer, M. and Scharmann, A. Techniques and Management of Personnel Thermoluminescence Dosimetry Services, Euro Courses. Kluwer Academic Publishers for the Commission of the European Communities, 1993.

4. DIN - Deutsches Institut für Normung. Neutron dosimetry – Part 4: measurement technique for individual dosimetry using albedo dosemeters. DIN 6802-4, German text. Beuth Verlag, 1998.

5. FERREIRA, M. S.; Silva, E. R.; Maurício, C. L. P. Assessment of neutron Hp(10) using workplace correction factors obtained through Monte Carlo simulation for alnor albedo dosemeter. Manuscript submitted for publication, 2021.