Real-time three-dimensional transthoracic echocardiography in quantification of left ventricular dyssynchrony

Author:

Mamedova A. I.1ORCID,Prihod’ko N. A.2ORCID,Lubimceva T. A.2ORCID,Kozlenok A. V.2,Lebedev D. S.2ORCID

Affiliation:

1. FSBI «Almazov NMRC» of the MH RF; Saint-Petersburg Institution of Healthcare «City Hospital №2»

2. FSBI «Almazov NMRC» of the MH RF

Abstract

Aim. To compare endocardial and epicardial left ventricular (LV) pacing using real-time electrocardiography (ECG)-synchronized three-dimensional echocardiography (3DE).Methods. Experimental intraoperative study included 88 points obtained from 12 patients with compensated heart failure of II-IV functional class NYHA (LV ejection fraction < 35%) and cardiac resynchronization therapy indications - ECG pattern of complete left bundle branch block (LBBB) and QRS complex duration > 150 ms. During isolated LV pacing as part of cardiac resynchronization therapy implantation procedure endocardial and epicardial stimulation points matched under fluoroscopic control using quadripolar coronary sinus leads and endocardial electrodes for temporary pacing were obtained. The overall number of corresponding pacing sites included 44 endocardial and 44 epicardial stimulation positions. The mean age of patients was 68.5 [63; 73.5] years, 83% males (n=10). Before study enrollment, 12-channel ECG, echocardiography, and a six-minute walk test were performed for all participants along with cardiac magnetic resonance imaging and control coronary angiography if indicated. The prevalence of coronary heart disease was 50% (n=6) while dilated cardiomyopathy was the most common etiology of chronic heart failure in other cases. Intraoperative ECG with estimation of paced QRS complex morphology at each point was registered via LabSystem Pro Electrophysiological Recording System (Bard Electrophysiology, USA). 3DE was performed using TomTec and Philips Qlab 3DQ Advanced software (Philips Medical Systems, USA).Results. Three-dimensional parametric imaging of LV regional segmental excursion and myocardial contractility using 3DE revealed statistically significant difference in semi-quantative parameters such as ExcAvg (p<0.001), ExcMax (p=0.001), ExcMin (p<0.001) and LV ejection fraction based on 3D modelling (p=0.003) while endocardial pacing was more beneficial. During the course of endocardial stimulation, the 3DE dyssynchrony index estimated at the 2nd stimulation site was also significantly lower (p=0.03). Identical dyssynchrony parameters valid for the 16 and 12-segment 3D models (SDI-16, Tmsv-12SD) (at p=0.06) demonstrated only a tendency for significant difference. The duration of QRS complex at the time of endocardial pacing was significantly shorter (<190 [179;215] ms) (p=0.0008). Semi-quantitative and quantitative 3DE parameters showed the benefit of endocardial pacing resulting in cardiac contractility improvement with less dyssynchrony and LV volume reducing during intraoperative period.Conclusion. Endocardial pacing has potential benefit over the epicardial pacing represented by intraoperative dynamics of LV global and local contractility, intraventricular dyssynchrony estimated by 3DE and also ECG criteria. 3DE is helpful in more precise and reproducibile determing of late activation zone for target LV lead placement that is more manoeuvrable in case of endocardial stimulation.

Publisher

Institute of Cardio Technics - INCART

Subject

Pharmacology (medical),Cardiology and Cardiovascular Medicine,Emergency Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3