«Complete» and «incomplete» ablation lines for radiofrequency isolation of the pulmonary veins - is there a difference in reconnection and clinical efficacy?

Author:

Kozlov A. V.1,Durmanov S. S.1,Bazylev V. V.1

Affiliation:

1. Federal Center for Cardiovascular Surgery of the Ministry of Health of the Russian Federation

Abstract

Purpose. To compare the effect of the completed and incomplete ablation lines on the permanent isolation of the pulmonary veins (PV) during intracardiac electrophysiological (EP) examination 3 months after the operation, as well as to assess the frequency of recurrence of atrial fibrillation (AF) and its relationship with the reconnection in the PV.Methods. From January to December 2016, 60 patients with paroxysmal AF selected and operated. Patients were randomized into two groups in a 1:1 ratio. In the first group, after achieving isolation of PV, radiofrequency (RF) exposure continued until an anatomically continuous line of ablation was created. In the second group, after receiving electrical isolation of all PV, RF ablation was interrupted regardless of the anatomical completeness of the ablation line. After 3 months in a planned manner (regardless of clinical status), an endocardial EP study was performed to check the consistency of the input and output block of excitation in each PV and, if necessary, repeated RF ablation of the reconnection sites.Results. A total of 53 people completed the study. In the first group intracardiac EP examination was performed on 29 patients, in the second group - on 24 patients. In the first group 4 patients retained isolation of all PV (13.8%), and in the second group - 5 (20.8%). No significant difference between the groups was obtained (p = 0.267). Sinus rhythm 3 months after the first procedure was observed in 28 patients (52.8%), of which 78.5% had reconnection in at least one PV. The recurrence rate of AF between the groups did not differ (OR 0.488 95% CI 0.162-1.460 p = 0.563) In the first group after 15 months the sinus rhythm was observed in 19 of 29 patients (65.5%), in the second group in 18 of 24 patients (75%). Differences are not statistically significant (OR 0.633 95% CI 0.191-2.103 p = 0.612)Conclusions: in our study, there was no significant difference in the frequency of reconnection and the clinical efficacy of RF isolation of PV in groups with complete and incomplete ablation lines.

Publisher

Institute of Cardio Technics - INCART

Subject

Marketing,Organizational Behavior and Human Resource Management,Strategy and Management,Drug Discovery,Pharmaceutical Science,Pharmacology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3