CorMatrix Anterior Leaflet Augmentation of the Tricuspid Valve: Midterm Results

Author:

Rescigno Giuseppe,Hothi Sandeep,Bond Christopher,Uddin Mauin,Bhatti Veena,Billing John Stephen

Abstract

Background: Tricuspid annuloplasty is the most common surgical approach to correct tricuspid regurgitation (TR). In some patients, however, anterior leaflet patch augmentation may be necessary to optimize tricuspid competence. We reviewed our center cohort over the midterm and long term. Methods: From January 2013 to August 2018, 424 tricuspid valve procedures were performed, of which 420 were repairs and 4 were replacements. Indications were either isolated severe TR or moderate or greater TR, concomitant with other surgery. In the repair cohort, we identified those that had a patch augmentation, and the database was interrogated for preoperative characteristics. The resulting patients had outpatient assessment (clinical and echocardiography) at 6 weeks and at a later interval. Additionally, a comparison was made between those who had good and poor results (moderate or greater TR or cardiac death). Results: In the repair cohort, 19 patients underwent complex tricuspid valve repair with CorMatrix anterior leaflet augmentation. Preoperative characteristics were as follows: age, 65.5 ± 13.5 years; New York Heart Association (NYHA) class, 3.5 ± 0.5; left ventricular ejection fraction, 48.3% ± 5.9%; tricuspid annular plane systolic excursion, 17.1 ± 3.7 mm; right ventricle (good, mild, moderate, poor), 10, 5, 4, 0; annulus size, 40.9 ± 6.9 mm; mean tethering distance, 1.00 ± 0.3 cm; and mean tethering area, 1.53 ± 1.16 cm2. Mean follow-up was 2.1 ± 1.9 years, and survival at 2 years was 73.8%. There were 2 in-hospital deaths. Mean NYHA class was 1.0 ± 0.5 (6 weeks) and 1.5 ± 0.6 (later follow-up); mean residual TR grade was 0.5 ± 0.6 (6 weeks) and 1.3 ± 1.4 (follow-up). Ten of 13 survivors had a good result at last follow-up (TR 0 to 1). We compared the preoperative and operative data of this group versus those with poor results (TR >1 or cardiac mortality). Significant univariate predictors of poor results were larger preoperative tethering area (1.18 ± 0.43 versus 2.4 ± 1.5 cm2; P = .02), longer tethering distance (0.87 ± 0.21 versus 1.2 ± 0.19 cm; P = .007), or the presence of mild or greater TR at 6 weeks (0.2 ± 0.4 vs 1.25 ± 0.5; P = .03). Conclusions: CorMatrix anterior leaflet augmentation produces successful, stable repair in the majority of this complex population. The presence of even mild TR at 6 weeks’ follow-up predicts a poor result. When the tethering area or the tethering distance is significantly high, replacement is probably a better option.

Publisher

Carden Jennings Publishing Co.

Subject

Cardiology and Cardiovascular Medicine,Surgery,General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3