A Comparison of Haemodynamic Responses between Clinical Assessments Guided Tracheal Intubation and Neuromuscular Block Monitoring Guided Tracheal Intubation

Author:

Malipatil Nidhi,Harshavardhan K.

Abstract

BACKGROUND During the induction of general anaesthesia (GA), laryngoscopy and endotracheal intubation produce significant nociceptive stimuli, which frequently results in inadvertent activation of the sympathetic nervous system. To blunt this pressor response, many drugs are successfully used. However, administration of an additional drug might cause adverse haemodynamic effects or might unnecessarily increase the depth of anaesthesia. Hence, a non-pharmacological measure to reduce the response is preferred. In this study, we wanted tocompare haemodynamic responses between clinical assessment-guided tracheal intubation and neuromuscular block monitoring-guided tracheal intubation. METHODS An observational study was conducted on 62 patients aged 18 – 60 years old belonging to American Soceity of Anaesthesiologist (ASA) I & II posted for surgeries under general anaesthesia were allotted to 2 groups of 31 each. In Group C patients, the trachea was intubated after the clinical judgment of jaw muscle relaxation. In Group M patients, the trachea was intubated after train of four counts became zero in adductor pollicis muscle. Changes in heart rate [HR], mean arterial blood pressure [MAP], Krieg’s intubation score, time between the administration of a neuromuscular blocking agent and endotracheal intubation were recorded. The collected data was analysed by mean, standard deviation, frequency, percentage, ttest and chi square test. RESULTS HR and mean arterial pressure were significantly higher in Group C as compared to Group M after laryngoscopy and tracheal intubation (P < 0.05). The mean time required for intubation was significantly shorter in Group C compared to Group M (179.52 ± 2 s vs. 358.19 ± 55 s). Excellent and good intubation conditions were observed in all Group M patients, whereas 24 out of 31 patients (77 %) in Group C showed excellent and good intubation conditions. CONCLUSIONS Haemodynamic responses to laryngoscopy and tracheal intubation can be significantly attenuated if tracheal intubation is performed following complete paralysis of laryngeal muscles, detected by neuromuscular monitoring of adductor pollicis muscle. KEY WORDS Laryngoscopy, Intubation, Haemodynamic Responses, Stress Response, Neuromuscular Monitor.

Publisher

Akshantala Enterprises Private Limited

Subject

General Medicine

Reference17 articles.

1. Reduction by fentanyl of the Cp50 values of propofol and hemodynamic responses to various noxious stimuli;Kazama;Anesthesiology,1997

2. Controlling the hemodynamic response to laryngoscopy and endotracheal intubation;Kovac;J Clin Anesth,1996

3. [3] Angelard B, Debry C, Planquart X, et al. Difficult intubations. A prospective study. Ann Otolaryngol Chir Cervicofac 1991;108(4):241-3.

4. A comparison of intubating conditions in children following induction of anaesthesia with propofol and suxamethonium or propofol and remifentanil;Morgan;Anaesthesia,2007

5. Monitoring techniques: neuromuscular blockade;AM;Anesth Intensive Care Med,2005

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3