Repeatability and agreement of total corneal astigmatism measured in keratoconic eyes using four current devices

Author:

Feng Yue1,Nitter Tore,Bertelsen Geir12,Stojanovic Aleksandar23ORCID

Affiliation:

1. Institute of Community Medicine, Faculty of Health Sciences University in Tromsø Tromsø Norway

2. Department of Ophthalmology University Hospital North Norway Tromsø Norway

3. Institute of Clinical Medicine, Faculty of Health Sciences University in Tromsø Tromsø Norway

Abstract

AbstractBackgroundTo evaluate repeatability and agreement in measurements of total corneal astigmatism (TCA) in keratoconic eyes, using four optical coherence tomography (OCT)‐based devices: Anterion, Casia SS‐1000, IOLMaster 700, and MS‐39.MethodsThree consecutive measurements were taken with each device in 136 eyes. TCA values were converted into components J0 and J45. The Anterion and the IOLMaster 700 also provided axial length (AL) measurements. The repeatability was calculated using pooled within‐subject standard deviation (Sw). The agreement among the four devices was assessed by pairwise comparisons and Bland–Altman plots.ResultsFor all devices, the repeatability of TCA measurements showed Sw ≤0.23 D for TCA magnitude, ≤0.14 D for J0, and ≤0.12 D for J45. There were statistically significant differences in TCA magnitude for each pair, except for IOLMaster 700 with MS‐39, and Anterion with MS‐39. The repeatability (Sw) of axis measurements had a statistically significant negative correlation with the TCA magnitude (p < 0.001 for all devices). Both Anterion and IOLMaster 700 had high repeatability in AL measurements (Sw: 0.007 mm for Anterion and 0.009 mm for IOLMaster 700). The difference in AL between the two was 0.015 ± 0.033 mm (p < 0.001).ConclusionsAll four devices showed good repeatability in TCA measurements in keratoconic eyes, the agreement for TCA measurements between the tested devices was generally low. Anterion and IOLMaster 700 showed good repeatability and agreement in AL measurements.

Funder

Norges Forskningsråd

Publisher

Wiley

Reference54 articles.

1. Biomicroscopic signs and disease severity in keratoconus;Zadnik K;Cornea,1996

2. A 48‐year clinical and epidemiologic study of keratoconus;Kennedy RH;Am J Ophthalmol,1986

3. Histopathologic findings of keratoconus corneas underwent penetrating keratoplasty according to topographic measurements and keratoconus severity;Naderan M;Int J Ophthalmol,2017

4. An in depth analysis of histopathological characteristics found in keratoconus;Sykakis E;Pathology,2012

5. Biomechanical properties of keratoconus and normal corneas;Andreassen TT;Exp Eye Res,1980