Validation of a Wearable System for Lower Extremity Assessment

Author:

Zhang Haohua1ORCID,Song Yang1,Li Cheng1,Dou Yong1,Wang Dacheng1,Wu Yinyue2,Chen Xiaoyi2,Liu Di3

Affiliation:

1. Department of Orthopaedic Surgery Beijing Jishuitan Hospital Beijing China

2. Guoke Ningbo Life Science Research Institute Beijing China

3. Jiakang Zhongzhi Technology Company Beijing China

Abstract

ObjectiveRemote assessment and diagnosis of functional impairment caused by osteoarthritis (OA) of the knee can achieve early intervention of patients’ functional impairment, prevent the deterioration of OA of the knee, and provide functional remote screening for patients with knee OA. This study introduced an inertial measurement unit (IMU) sensor‐based system to assess lower extremity function and perform gait analysis. Then, we compared its accuracy to gold‐standard motion capture and gait measurement systems.MethodsNine adults were selected to participate in a comparative study of gait assessment outcomes using an IMU sensor‐based wearable system, a gold‐standard motion capture system, and a pressure‐based gait analysis system. The subject walked on a path that incorporated all three systems. Data analysis was performed on spatiotemporal gait parameters, including velocity, cycle time, cadence, and stride length. This was followed by gait phases, including stance, swing, double stance, and single limb support phases. Data were processed using the data processing software of each system. An independent sample t‐test was conducted for inter‐group comparison to analyze the data.ResultsThe spatiotemporal gait parameters of the systems demonstrated excellent consistency, and the gait phases showed high consistency. Compared to the gold‐standard pressure‐based gait analysis system (the GATERite system), the mean gait cycle time results were 1.124 s vs. 1.127 s (p = 0.404); cadence was 93.333 steps/min vs. 94.189 steps/min (p = 0.482); stance phase was 60.89% vs. 63.26% (p < 0.001); swing phase was 39.11% vs. 36.74% (p < 0.001); stride length was 1.404 m vs. 1.420 m (p = 0.743); speed was 1.093 m/s vs. 1.110 m/s (p = 0.725). Compared to the gold‐standard video‐based motion capture system, the root mean square error was 2.7° for the hip angle and 2.6° for the knee angle.ConclusionsThis IMU‐based wearable system delivered precise measuring results to evaluate patients with knee OA. This technology can also be used to guide rehabilitation exercises for patients with knee OA.

Publisher

Wiley

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3