Longitudinal changes in diffusion tensor imaging in hemodialysis patients

Author:

Richerson Wesley T.1ORCID,Schmit Brian D.1,Wolfgram Dawn F.23

Affiliation:

1. Department of Biomedical Engineering Marquette University and Medical College of Wisconsin Milwaukee Wisconsin USA

2. Department of Medicine Medical College of Wisconsin Milwaukee Wisconsin USA

3. Zablocki Veterans Affairs Medical Center Milwaukee Wisconsin USA

Abstract

AbstractIntroductionHemodialysis patients have increased white matter and gray matter pathology in the brain relative to controls based on MRI. Diffusion tensor imaging is useful in detecting differences between hemodialysis and controls but has not identified the expected longitudinal decline in hemodialysis patients. In this study we implemented specialized post‐processing techniques to reduce noise to detect longitudinal changes in diffusion tensor imaging parameters and evaluated for any association with changes in cognition.MethodsWe collected anatomical and diffusion MRIs as well as cognitive testing from in‐center hemodialysis patients at baseline and 1 year later. Gray matter thickness, white matter volume, and white matter diffusion tensor imaging parameters were measured to identify longitudinal changes. We analyzed the diffusion tensor imaging parameters by averaging the whole white matter and using a pothole analysis. Eighteen hemodialysis patients were included in the longitudinal analysis and 15 controls were used for the pothole analysis. We used the NIH Toolbox Cognition Battery to assess cognitive performance over the same time frame.FindingsOver the course of a year on hemodialysis, we found a decrease in white matter fractional anisotropy across the entire white matter (p < 0.01), and an increase in the number of white matter fractional anisotropy voxels below pothole threshold (p = 0.03). We did not find any relationship between changes in whole brain structural parameters and cognitive performance.DiscussionBy employing noise reducing techniques, we were able to detect longitudinal changes in diffusion tensor imaging parameters in hemodialysis patients. The fractional anisotropy declines over the year indicate significant decreases in white matter health. However, we did not find that declines in fractional anisotropy was associated with declines in cognitive performance.

Funder

National Institutes of Health

National Institute of Diabetes and Digestive and Kidney Diseases

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3