Influence of metal artefact reduction on the diagnosis of contact between implant and mandibular canal in cone beam computed tomography: An ex‐vivo study

Author:

de Freitas Bruna Neves1ORCID,da Motta Raphael Jurca Gonçalves1ORCID,Pauwels Ruben23ORCID,Oliveira‐Santos Christiano4ORCID,Tirapelli Camila1ORCID

Affiliation:

1. Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirão Preto University of São Paulo São Paulo Brazil

2. Department of Dentistry and Oral Health Aarhus University Aarhus Denmark

3. Department of Radiology, Faculty of Dentistry Chulalongkorn University Bangkok Thailand

4. Department of Diagnosis & Oral Health University of Louisville School of Dentistry Louisville Kentucky USA

Abstract

AbstractObjectiveTo evaluate the influence of metal artefact reduction (MAR) in the diagnosis of dental implant contact with the mandibular canal (MC) using cone beam computed tomography (CBCT).MethodsDental implants were installed with surgical guides in the posterior hemiarches of 10 dry human mandibles: 0.5 mm above to the MC cortex (G1/n = 8) and 0.5 mm inside the MC (G2/n = 10). The experimental set‐up was scanned with two CBCT equipment using 85 kV and 90 kV, MAR ON or OFF, and different tube currents (4 mA, 8 mA and 10 mA). Two dentomaxillofacial radiologists (DMFRs) and two dentists (DDS) scored the relation between the dental implant and MC. Descriptive statistics were used to observe the absolute frequency of scores. Sensitivity, specificity and accuracy were calculated considering the known relation between the dental implant and the MC interior. McNemar's test (α = .05) was applied to compare the diagnostic efficacy of MAR ON versus MAR OFF.ResultsOverall specificity was higher than sensitivity for both DDS and DMFR (97% vs. 50% and 92.0% vs. 78.0% respectively). There was a significant effect of MAR (p = .031) for DMFR in the case of contact between the dental implant with the MC interior, in which sensitivity decreased with MAR activation from 90% to 40%. DMFR observers showed a better diagnostic performance compared with the DDS observers (accuracy of 84.0% and 71.0%, respectively).ConclusionsDue to the limited efficacy of MAR, it should not be used when conducting CBCT scans for the evaluation of contact between the implant and the mandibular canal.

Funder

Fundação de Amparo à Pesquisa do Estado de São Paulo

Publisher

Wiley

Subject

Oral Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3