Comparison of two CBCT analysis techniques with conventional periapical radiographs in assessment of tertiary dentin after indirect pulp capping in young permanent teeth

Author:

Baraka Marwa1ORCID,Cevidanes Lucia2,Ruellas Antonio3,Benavides Erika4,Aly Nourhan1ORCID,Fontana Margherita5

Affiliation:

1. Pediatric Dentistry and Dental Public Health Department, Faculty of Dentistry Alexandria University Alexandria Egypt

2. Department of Orthodontics and Pediatric Dentistry, School of Dentistry University of Michigan Ann Arbor Michigan USA

3. Department of Orthodontics Federal University of Rio de Janeiro Rio de Janeiro Brazil

4. Department of Periodontics and Oral Medicine, School of Dentistry University of Michigan Ann Arbor Michigan USA

5. Department of Cariology, Restorative Sciences and Endodontics, School of Dentistry University of Michigan Ann Arbor Michigan USA

Abstract

AbstractBackground and aimTo compare two cone beam computed tomography (CBCT) analysis techniques for measuring tertiary dentin (TD) volume, density, and root length increase, after indirect pulp therapy (IPT) in young permanent teeth with conventional periapical radiographs.DesignComparative study design: Sixty‐nine CBCT scans were taken initially (T1) and after 1 year (T2) of IPT. New CBCT analysis technique A, standardization, segmentation, and registration of T1 and T2 scans were performed using ITK‐SNAP and 3D Slicer CMF to measure TD volume (mm3), density (gray‐level intensity), and root length increase (mm). In the traditional CBCT analysis technique B, analyses were conducted using the In‐Vivo software to calculate TD thickness (mm), radiodensity (HU%), and root length increase (mm). Paired t‐test and the intraclass correlation coefficient were calculated to compare and assess the reliability of all techniques.ResultsNo significant difference between the two techniques existed in the measurement of TD mineral density (Mean [SD]:A = 22.4 [15.4]; B = 24.4 [15.4]; p = .47). Technique A resulted in significantly higher root length increase values (Mean [SD]: A = 1.3 [0.6]; B = 1.1 [0.5]; p = .03). The two techniques showed acceptable reliability levels (0.76–0.99).ConclusionCBCT analysis techniques yielded similar findings for mineral density. The new CBCT volumetric analysis technique, although more laborious, produced higher values for root length increase, and allowed for measurement of dentin volume.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3