Comparison of computer‐assisted sperm analysis and smartphone‐applied sperm analysis for evaluation of frozen–thawed bull semen

Author:

Baştan İlktan1ORCID

Affiliation:

1. Department of Reproduction and Artificial Insemination Faculty of Veterinary Medicine, Burdur Mehmet Akif Ersoy University Burdur Turkey

Abstract

AbstractThis study aims to compare the efficacy of computer‐assisted sperm analysis (CASA) and smartphone‐applied sperm analysis (SASA) in assessing the quality of frozen–thawed bull semen. A total of 75 straws (n = 75) semen samples were used from different production batches of five Holstein bulls. The semen analyses were conducted in three groups: Group I (CASA‐37°C), semen samples were evaluated using the CASA system at 37°C (n = 25); Group II (SASA‐25°C), semen samples were assessed using the SASA system at a temperature of room heat (25°C) (n = 25); and Group III (SASA‐37°C), semen samples were evaluated using the SASA system at 37°C (n = 25). The frozen–thawed bull semen samples were analysed in terms of total motility (TM), progressive motility (PM), immotile, velocity average path (VAP), velocity curve linear (VCL), velocity straight line (VSL) and sperm concentration. There was no significant difference between the groups in terms of spermatozoa concentration (p > .05). However, significant differences among the groups were observed for total motile spermatozoa values (p < .001). Values of progressive motile spermatozoa were lower in Group I and Group II compared to Group III (p < .001). The immotile spermatozoa values were significant between the groups (p < .001) and were found to be proportional to total motile spermatozoa values. Additionally, the VAP, VCL and VSL values were comparable between Group II and Group III, but lower when compared to Group I. In conclusion, the results of the study demonstrate that the Sperm Cell™ system can accurately analyse the concentration of frozen–thawed bull semen. The analyses performed at room temperature indicate a parallelism between the PM value and CASA results. However, it is thought that SASA devices require a series of standardization studies in different semen extenders, different sample concentrations and different animal species, analogous to the standardization evolution process of CASA devices in semen analysis.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3