Comparative evaluation of Duragen® and skim milk extenders to enhance ram semen quality and fertility: A promising alternative in ovine artificial insemination

Author:

El Amiri Bouchra12,Ben Moula Anass1ORCID,El Khelfaoui Nora1,Rahim Abdellatif1,Gyoker Erzsebet3,Horváth András4ORCID,Szenci Ottó4ORCID

Affiliation:

1. Animal Production Unit Regional Center Agricultural Research of Settat National Institute for Agricultural Research (INRA) Rabat Morocco

2. African Sustainable Agriculture Research Institute (ASARI) Mohammed VI Polytechnic University (UM6P) Laayoune Morocco

3. Biotechnical Research Station Pharmagene‐Farm Ltd. Mosonmagyarovar Hungary

4. Department of Obstetrics and Food Animal Medicine Clinic University of Veterinary Medicine Budapest Budapest Hungary

Abstract

AbstractThis study aimed to investigate the effectiveness of Duragen® and skimmed milk (SM) extenders on the quality parameters, bacterial load and fertilization ability of stored ram semen. A total of 50 ejaculates from Sardi rams (n = 5) aged 2.5–3 years, were collected and stored in Duragen® and SM at 15°C. The motilities and velocity parameters generated by the CASA system were then evaluated at 0, 8 and 24 h of storage. Afterward, bacterial loads of sperm extended in Duragen® and SM were determined at 0, 5 and 24 h of incubation. In addition, ewes (n = 100) aged 2 years, have been chosen in the same herd. The selected ewes were then synchronized and inseminated using semen extended in Duragen® and SM and stored for 5 h at 15°C. The results revealed that total and progressive motilities, straight velocity (VSL), straightness (SRT), lateral head displacement (ALH) and beat cross frequency (BCF) were not affected by the extender type after 24 h of storage (p > .05). However, curvilinear velocity (VCL), velocity average path (VAP), linearity (LIN) and wobble (WOB) showed higher values in Duragen® compared with SM extender after 24 h of storage (p < .05). Bacterial loads were observed mainly in sperm stored in SM at 5 h (183 UFC/mL) and at 24 h (357 UFC/mL) of incubation. However, the only case showing a bacterial load in Duragen® is when the storage time attains 24 h (199 UFC/mL). Concerning fertility, sperm diluted in both extenders resulting in high fertility rates which reaches 66% and 73% for Duragen® and SM, respectively, with no statistical difference (p > .05). In summary, Duragen® extender decreased bacterial load in stored semen and maintained high ram sperm quality and fertility. These findings suggest that Duragen® extender could be used as SM alternative in ovine artificial insemination (OAI).

Publisher

Wiley

Subject

Endocrinology,Animal Science and Zoology,Biotechnology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3