Standardization and validation of neoLVOT assessment using three‐dimensional trans‐esophageal echocardiography before trans‐catheter mitral valve replacement

Author:

Hekal Soha1,Emam Amr Y.1,Thabet Nagwa12,Shaaban Mahmoud13,Bahaa Hesham14,Elguindy Ahmed1,Mahmoud‐Elsayed Hani1ORCID

Affiliation:

1. Adult Cardiology department, Aswan Heart Centre Magdi Yacoub Foundation Aswan Egypt

2. Cardiology department Aswan University Aswan Egypt

3. Cardiology department Tanta University Tanta Egypt

4. Cardiology department National Heart Institute Cairo Egypt

Abstract

AbstractBackgroundTrans‐catheter mitral valve replacement (TMVR) procedures had emerged as an alternative solution for patients who are at high risk for mitral valve surgery. Although cardiac computed tomography (CT) remains the standard method for procedural planning, there is no full agreement on the best systolic phase for quantitation of the neoLVOT. Furthermore, a new three‐dimensional trans‐esophageal echocardiography (3DTEE) based software was developed to serve as filter and or an alternative for patients who cannot have CT due to any contraindication.AimTo determine the systolic phase of the cardiac cycle that shows the narrowest NeoLVOT area in order to standardize the way of using these software and then to validate the 3DTEE‐based software against the CT‐based one as a gold standard, in mitral valve annulus (MA) and NeoLVOT assessment.MethodsA single center, observational, retrospective study. Initially, a sample of 20 patients (age 62 ± 4 years, 70% men) had CT‐based analysis at mid‐diastole (80%), early‐systole (10%), mid‐systole (20%), late‐systole (30%–40%), in order to detect the best systolic phase at which the neoLVOT area is the narrowest after TMVR. Then, the end systolic phase was standardized for the analysis of 49 patients (age 57 ± 6 years, 60% men), using both the commercially available CT‐based software and the newly available 3DTEE‐based software (3mensio Structural Heart, Pie Medical Imaging, The Netherlands). The 3DTEE derived parameters were compared with the gold standard CT‐based measurements.ResultsThe neoLVOT area was significantly narrower at end‐systole (224 ± 62 mm2), compared to early‐systole (299 ± 70 mm2) and mid‐systole (261 ± 75 mm2), (p = .005). Excellent correlation was found between 3DTEE and CT measurements for MA AP diameter (r = .96), IC diameter (r = .92), MA area (r = .96), MA perimeter (r = .94) and NeoLVOT area (r = .96), (all p‐values < .0001). Virtual valve sizing was based on annulus measurement and was identical between CT and 3DTEE. Interobserver and intraobserver agreements were excellent for all the measurements with ICCs > .80.ConclusionsEnd‐systole is the phase that shows the narrowest neoLVOT and hence should be the standard phase used during the analysis. The 3DTEE based analysis using this new software is reliable compared to the CT‐based analysis and can be serve as an alternative analysis tool in patients who cannot have CT for any clinical contraindication or as a screening test and/or filter for all patients before proceeding to a detailed CT scan.

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3