Effects of screw channel angulation on the fracture resistance of one‐piece zirconia crown with titanium base

Author:

Wei Chen‐xuan1ORCID,Saglik Berna1,Sung Hsieh Hsiao Hsin2,Guram Paramvir Singh J.3

Affiliation:

1. Department of Biologic and Materials Sciences and Prosthodontics University of Michigan Ann Arbor Michigan USA

2. Department of Oral & Maxillofacial Surgery / Hospital Dentistry University of Michigan Ann Arbor Michigan USA

3. Department of Cariology Restorative Sciences and Endodontics University of Michigan Ann Arbor Michigan USA

Abstract

AbstractPurposeThe design of the angulated screw channel in implant restorations allows the possibility to correct angulation discrepancies, especially in the anterior maxilla. However, the effects of varied screw channel angulations on fracture resistances and fracture patterns of the implant restorations are still uncertain, and thus the aim of this study.Materials and MethodsAngulated screw channel monolithic zirconia crowns (Nobel Biocare) with three different angulation groups—straight (ASC1), 15° (ASC15), and 25° (ASC25)—were digitally designed from a left central incisor prototype scan. Following fabrication, 10 samples of each group were individually mounted onto implant replicas embedded in standardized type V stone gypsum cylinder jigs (25 mm × 25 mm). All screws were manually torqued to 35 Ncm according to the manufacturer's recommendation, and screw access openings were subsequently sealed with resin composite. To mimic the off‐axis loading of the central incisor, the specimens were then loaded at a cephalometric interincisal relationship of 135° between the long axis of the crown and the Instron force applicator, with crosshead speed set at 0.5 mm/min. Fractured abutment surfaces were examined, and selected specimens were further evaluated by scanning electron microscopy. Screw torque values were also measured after the catastrophic loading. One‐way ANOVA was used to compare load‐to‐fracture values between groups, with the statistical significance set at 0.05 (p values).ResultsThe mean load‐to‐fracture values in descending order were 331.24N (±34.00N) in ASC15, 325.22N (±35.50N) in ASC25, and 302.04N (±45.10N) in ASC1, with no statistically significant differences between groups. Considerable screw torque losses were found in all groups after catastrophically loading. The average torque loss was 84% in ASC1, 86% in ASC15, and 94% in ASC25. 16 out of 30 specimens experienced screw loosening; one ASC1 screw underwent slight deformation. Crowns of all tested groups exhibited cohesive fracture patterns at the screw‐metallic‐zirconia interfaces.ConclusionsWithin the limitations of this in vitro study, one‐piece monolithic zirconia implant crowns with varied screw channel angulations shared similar fracture‐strength and fracture‐mode characteristics. The zirconia‐titanium base junctions exhibited the weakest link of all restorations.

Publisher

Wiley

Subject

General Dentistry

Reference43 articles.

1. Prosthetic Design Considerations for Anterior Single-Implant Restorations

2. Screw- Versus Cement-Retained Implant Restorations: Current Concepts

3. The influence of abutment angulation on micromotion level for immediately loaded dental implants: a 3‐D finite element analysis;Kao H‐C;Int J Oral Maxillofac Implants.,2008

4. Influence of Implant Angulation on the Fracture Resistance of Zirconia Abutments

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3