Surface hardness and wear resistance of prefabricated and CAD‐CAM milled artificial teeth: A cross‐over clinical study

Author:

Ali Sarah Abdelaal1ORCID,Abozaed Heba Wageh23ORCID,Jazar Husn A.4ORCID,Mostafa Aisha Z. H.2ORCID

Affiliation:

1. External Residence of Prosthodontics Faculty of Dentistry Mansoura University Mansoura Egypt

2. Department of Prosthodontics Faculty of Dentistry Mansoura University Mansoura Egypt

3. Prosthodontics Department College of Dentistry Prince Sattam Bin Abdulaziz University, Al‐Kharj Riyadh Saudi Arabia

4. Dental Biomaterials Department Faculty of Dentistry Mansoura University Mansoura Egypt

Abstract

AbstractPurposeTo clinically evaluate the surface roughness and wear resistance of prefabricated and CAD‐CAM milled acrylic resin teeth for complete dentures.Materials and methodsIn a cross‐over study design, 10 completely edentulous patients were randomly included in this study and given two complete dentures. The first complete denture was made using prefabricated teeth, while the second was constructed using CAD‐CAM milled teeth. Following insertion (T0), 3 months (T3), and 6 months (T6), the complete dentures were scanned. Utilizing 3D surface super‐imposition techniques, the vertical (2D wear), and volumetric (3D wear) material loss were measured. The hardness of the teeth was evaluated at the time of denture insertion (T0) and then after 6 months (T6) of denture insertion by digital Vickers hardness tester. Statistical analysis was done using SPSS software. Paired groups were compared by paired t‐test. Also, a repeated measure test was used. The significant difference was considered if p ≤ 0.05.ResultsThe time of denture function was linearly correlated with the wear of the prefabricated and CAD‐CAM milled denture tooth. Prefabricated acrylic teeth had significantly more vertical and volumetric wear after 3 and 6 months, compared to CAD‐CAM milled denture teeth where p‐values were 0.01, 0.009, 0.003, and 0.024, respectively. Additionally, CAD‐CAM milled teeth displayed significantly higher hardness values than prefabricated teeth both before and after 6 months of use where p‐values were 0.001. After 6 months, all studied teeth showed a decrease in their hardness.ConclusionsIn terms of wear resistance and surface hardness, CAD‐CAM milled acrylic resin teeth were superior to prefabricated acrylic resin artificial teeth once the complete denture functions.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3