Depth distortion and angular deviation of a fully guided tooth‐supported static surgical guide in a partially edentulous patient: A systematic review and meta‐analysis

Author:

Floriani Franciele1ORCID,Jurado Carlos A.2ORCID,Cabrera Alexandre J.3ORCID,Duarte Wagner4ORCID,Porto Thiago S.5ORCID,Afrashtehfar Kelvin I.67ORCID

Affiliation:

1. Department of Prosthodontics The University of Iowa College of Dentistry and Dental Clinics Iowa City Iowa USA

2. Division of Operative dentistry Department of General Dentistry The University of Tennessee Health Science Center College of Dentistry Memphis Tennessee USA

3. Department of Restorative Dental Sciences University of Florida College of Dentistry Gainesville Florida USA

4. Interim Department Chair Department of Periodontology University of Florida College of Dentistry Gainesville Florida USA

5. Assistant Professor Department of Operative Dentistry The University of Iowa College of Dentistry and Dental Clinics Iowa City Iowa USA

6. Director of Evidence‐Based Practice Unit, Clinical Sciences Department College of Dentistry Ajman University Ajman City United Arab Emirates

7. Department of Reconstructive Dentistry and Gerodontology School of Dental Medicine University of Bern Bern Switzerland

Abstract

AbstractPurposeThis systematic review and meta‐analysis aimed to evaluate the depth distortion and angular deviation of fully‐guided tooth‐supported static surgical guides (FTSG) in partially edentulous arches compared to partially guided surgical guides or freehand.Material and MethodsThis study followed the Preferred Reporting Items for Systematic Reviews and Meta‐Analyses (PRISMA) guidelines and was registered in the Open Science Framework (OSF). The formulated population, intervention, comparison, and outcome (PICO) question was: “In partially edentulous arches, what are the depth distortion and angular deviation of FTSG compared to partially guided surgical guides or freehand?” The search strategy involved four main electronic databases, and an additional manual search was completed in November 2023 by following an established search strategy. Initial inclusion was based on titles and abstracts, followed by a detailed review of selected studies, and clinical studies that evaluated the angular deviations or depth distortion in FTSG in partial arches, compared to partially guided surgical guides or freehand, were included. In FTSG, two surgical approaches were compared: open flap and flapless techniques, and two digital methods were assessed for surgical guide design with fiducial markers or dental surfaces. A qualitative analysis for clinical studies was used to assess the risk of bias. The certainty of the evidence was assessed according to the grading of recommendations, assessment, development, and evaluations (GRADE) system. In addition, a single‐arm meta‐analysis of proportion was performed to evaluate the angular deviation of freehand and FTSG.ResultsTen studies, published between 2018 and 2023, met the eligibility criteria. Among them, 10 studies reported angular deviations ranging from ‐0.32° to 4.96° for FTSG. Regarding FTSG surgical approaches, seven studies examined the open flap technique for FTSG, reporting mean angular deviations ranging from 2.03° to 4.23°, and four studies evaluated flapless FTSG, reporting angular deviations ranging from ‐0.32° to 3.38°. Six studies assessed the freehand surgical approach, reporting angular deviations ranging from 1.40° to 7.36°. The mean depth distortion ranged between 0.19 mm to 2.05 mm for open flap FTSG, and between 0.15 mm to 0.45 mm for flapless FTSG. For partially guided surgical guides, two studies reported angular deviations ranging from 0.59° to 3.44°. Seven studies were eligible for meta‐analysis, focusing on the FTSG in open flap technique, with high heterogeneity (I2 (95%CI) = 92.3% (88.7%–96.4%)). In contrast, heterogeneity was low in studies comparing freehand versus FTSG in open flap techniques (I2 (95%CI) = 21.3% (0.0%–67.8%)), favoring the FTSG surgical approach.ConclusionIn partially edentulous arches, FTSG systems exhibited less angular deviation than freehand and partially guided surgical guides. Flapless surgical approaches were associated with reduced angular deviation and depth distortion, suggesting a potential preference for the FTSG method in these procedures.

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com