Abstract

AbstractBackgroundThe objective measurement for esophageal bolus volume and bolus clearance could classify abnormal high‐resolution manometry (HRM) beyond the current Chicago classification. We aimed to compare the novel four‐dimensional impedance manometry (4D HRM) volume metrics with timed barium esophagram (TBE).MethodsAdults with esophageal symptoms undergoing HRM and TBE were included. A custom‐built program for 4D HRM analysis measured esophageal luminal cross‐sectional area (CSA) from impedance and subsequently derived esophageal bolus volume and clearance. 4D HRM volume metrics included pre‐swallow residual volume, maximal volume, retention volume, and clearance ratio defined as 1.0—retention volume divided by the maximal volume. An abnormal TBE was defined as a column height >5 cm at 1 min or 5 min.Key ResultsA total of 95 patients (normal motility: 33%; ineffective esophageal motility: 12%; absent contractility: 10%; esophagogastric junction outflow obstruction: 30%; type I achalasia: 5%; type II achalasia: 12%) were categorized into normal TBE (58%), abnormal TBE at 1 min (17%), and abnormal TBE at 5 min (25%). The AUROC demonstrated that, among all 4D HRM volume metrics, the clearance ratio had the best performance in predicting abnormal TBE at 5 min (AUROC, 95% confidence interval: 0.89, 0.82–0.96), and exhibited a strong negative correlation with TBE at 5 min (r = −0.65; p < 0.001).Conclusions & InferencesNovel 4D HRM volume metrics provide objective measurement of esophageal bolus volume and bolus clearance. The clearance ratio has a strong correlation with TBE and could potentially serve as a substitute for TBE to measure esophageal retention.

Funder

U.S. Public Health Service

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3