Clinical validation of two volumetric absorptive microsampling devices to support home‐based therapeutic drug monitoring of immunosuppression

Author:

Leino Abbie D.1ORCID,Takyi‐Williams John2ORCID,Park Jeong M.1ORCID,Norman Silas P.3ORCID,Sun Duxin24ORCID,Farris Karen B.1ORCID,Pai Manjunath P.12ORCID

Affiliation:

1. Department of Clinical Pharmacy, College of Pharmacy University of Michigan Ann Arbor MI USA

2. Pharmacokinetic & Mass Spectrometry Core, College of Pharmacy University of Michigan Ann Arbor MI USA

3. Division of Nephrology, Department of Internal Medicine University of Michigan Ann Arbor MI USA

4. Department of Pharmaceutical Sciences, College of Pharmacy University of Michigan Ann Arbor MI USA

Abstract

AimsDried blood volumetric absorptive microsamples (VAMS) may facilitate home‐based sampling to enhance therapeutic drug monitoring after transplantation. This study aimed to clinically validate a liquid chromatography–tandem mass spectrometry assay using 2 VAMS devices with different sampling locations (Tasso‐M20 for the upper arm and Mitra for the finger). Patient preferences were also evaluated.MethodsClinical validation was performed for tacrolimus and mycophenolic acid by comparison of paired VAMS and venipuncture samples using Passing–Bablok regression and Bland–Altman analysis. Conversion of mycophenolic acid VAMS to serum concentrations was evaluated using haematocrit‐dependent formulas and fixed correction factors defined a priori. Patients' perspectives, including useability, acceptability and feasibility, were also investigated using established questionnaires.ResultsPaired samples (n = 50) were collected from 25 kidney transplant recipients. Differences for tacrolimus whole‐blood concentration were within ±20% for 86 and 88% of samples from the upper arm and fingerstick, respectively. Using correction factors of 1.3 for the upper‐arm and 1.47 for finger‐prick samples, 84 and 76% of the paired samples, respectively, were within ±20% for mycophenolic acid serum concentration. Patient experience surveys demonstrated limited pain and acceptable useability of the upper‐arm device.ConclusionsTacrolimus and mycophenolic acid can be measured using 2 common VAMS devices with similar analytical performance. Patients are supportive of home‐based monitoring with a preference for the Tasso‐M20 device.

Funder

College of Pharmacy, University of Michigan

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3