Allowable movement of wavefront‐guided contact lens corrections in normal and keratoconic eyes

Author:

Applegate Raymond A.1ORCID,Hastings Gareth D.1ORCID,Jiménez‐García Marta23ORCID,Francis Sharon2,Koppen Carina23ORCID,Rozema Jos J.23ORCID

Affiliation:

1. College of Optometry University of Houston Houston Texas USA

2. Visual Optics Lab Antwerp (VOLANTIS), Faculty of Medicine and Health Sciences Antwerp University Wilrijk Belgium

3. Department of Ophthalmology Antwerp University Hospital Edegem Belgium

Abstract

AbstractPurposeThe goal was to use SyntEyes modelling to estimate the allowable alignment error of wavefront‐guided rigid contact lens corrections for a range of normal and keratoconic eye aberration structures to keep objectively measured visual image quality at or above average levels of well‐corrected normal eyes. Secondary purposes included determining the required radial order of correction, whether increased radial order of the corrections further constrained the allowable alignment error and how alignment constraints vary with keratoconus severity.MethodsBuilding on previous work, 20 normal SyntEyes and 20 keratoconic SyntEyes were fitted with optimised wavefront‐guided rigid contact lens corrections targeting between three and eight radial orders that drove visual image quality, as measured objectively by the visual Strehl ratio, to near 1 (best possible) over a 5‐mm pupil for the aligned position. The resulting wavefront‐guided contact lens was then allowed to translate up to ±1 mm in the x‐ and y‐directions and rotate up ±15°.ResultsAllowable alignment error changed as a function of the magnitude of aberration structure to be corrected, which depends on keratoconus severity. This alignment error varied only slightly with the radial order of correction above the fourth radial order. To return the keratoconic SyntEyes to average levels of visual image quality depended on maximum anterior corneal curvature (Kmax). Acceptable tolerances for misalignment that returned keratoconic visual image quality to average normal levels varied between 0.29 and 0.63 mm for translation and approximately ±6.5° for rotation, depending on the magnitude of the aberration structure being corrected.ConclusionsAllowable alignment errors vary as a function of the aberration structure being corrected, the desired goal for visual image quality and as a function of keratoconus severity.

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Reimagining approaches to solving common contact lens conundrums;Ophthalmic and Physiological Optics;2024-04-26

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3