A prototype protocol for evaluating the real‐world data set using a structured electronic health record in glaucoma

Author:

Sulonen Sakari1,Leinonen Sanna12,Lehtonen Eemil1,Hujanen Pekko12,Vaajanen Anu3ORCID,Syvänen Ulla2,Hemelings Ruben456ORCID,Stalmans Ingeborg47ORCID,Tuulonen Anja2ORCID,Uusitalo‐Jarvinen Hannele12ORCID

Affiliation:

1. Faculty of Medicine and Health Technology Tampere University Tampere Finland

2. Tays Eye Centre Tampere University Hospital Tampere Finland

3. Eye and Vision Research SILK, Faculty of Medicine and Health Technology Tampere University Tampere Finland

4. Department of Neurosciences, Research Group Ophthalmology KU Leuven Leuven Belgium

5. Singapore Eye Research Institute, Singapore National Eye Centre Singapore Singapore

6. SERI‐NTU Advanced Ocular Engineering (STANCE) programme Singapore Singapore

7. Ophthalmology Department UZ Leuven Leuven Belgium

Abstract

AbstractPurposeAs the first step in monitoring and evaluating day‐to‐day glaucoma care, this study reports all real‐world data recorded during the first full year after the implementation of a prototype for glaucoma‐specific structured electronic healthcare record (EHR).MethodsIn 2019, 4618 patients visited Tays Medical Glaucoma Clinic at Tays Eye Centre, Tampere University Hospital, Finland, that serves a population of 0.53 M. Patient data were entered into a glaucoma‐specific EHR by trained nurses to be checked by glaucoma specialists. Tays Eye Centre follows the Finnish Current Care Guideline for glaucoma in which glaucoma is defined using a ‘2 out of 3’ rule, that is, ≥2 findings evaluated as glaucomatous in optic nerve head (ONH), retinal nerve fibre layer (RNFL) and visual field (VF).ResultsThe clinical evaluations of ONH, RNFL and VF were recorded in 95%–100% of all eyes. ONH was evaluated as glaucomatous more often (44%) than RNFL (33%) and VF tests (30%). Progressive changes in any of the three tests were recorded in 35% of the ‘≥2/3 glaucoma group’ compared to 2%–9% in the other groups. The mean IOP at visit was 15 mmHg. The mean target IOP was 17 mmHg, and it was recorded in 94% of eyes.ConclusionThe developed structured data presentation enables comparisons between different population‐based real‐world glaucoma data sets and glaucoma clinics. Compared to a data set from the UK, the proportion of glaucoma suspicion‐related visits was smaller in Tays Eye Centre and test intervals were longer.

Funder

Silmäsäätiö

Publisher

Wiley

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3