Differential diagnosis of lymphocytosis in routine laboratory practice: Contribution of lymphocyte parameters using the Sysmex‐XN9000 haematology analyzer

Author:

Poutakidou Danai1ORCID,Ruth Isabelle2,Gulbis Beatrice1

Affiliation:

1. Haematology Department, Laboratoire Hospitalier Universitaire de Bruxelles (LHUB‐ULB) Université Libre de Bruxelles Brussels Belgium

2. Immunology Department, Laboratoire Hospitalier Universitaire de Bruxelles (LHUB‐ULB) Université Libre de Bruxelles Brussels Belgium

Abstract

AbstractIntroductionThis study investigates the potential contribution of structural and dispersion parameters, as well as alarms provided by Sysmex XN9000 haematology analyzer. The objective was to assess the need for a microscopic examination in the context of lymphocytosis. It also aims to contribute in differentiating rapidly lymphoproliferative disorders such as chronic lymphocytic leukaemia (CLL), non‐chronic lymphocytic leukaemia (NON‐CLL) and non‐infectious reactive lymphocytosis (REAC).MethodsWe prospectively assessed lymphocyte parameters (Ly‐X, Ly‐Y, Ly‐Z, Ly‐WX, Ly‐WY, Ly‐WZ) provided by the Sysmex XN9000 analyzer; they were measured in the white blood cell differential (WDF) channel which also provides alarms via the precursor/pathological cellular channel (WPC). Blood samples from 71 subjects with CLL, NON‐CLL lymphoproliferative and REAC non‐infectious reactive lymphocytosis, as well as a control (NORM) group of 12 subjects without any abnormalities were analyzed.ResultsThe most discriminating parameters to distinguish the different groups were Ly‐X, Ly‐Z and Ly‐WZ. The lymphoid structural parameters Ly‐X and Ly‐Z significantly discriminated the CLL group from the other groups (p < 0.001), and the CLL group from the REAC group (p < 0.01), respectively. The Ly‐WZ parameter discriminated the CLL group from the NON‐CLL, REAC (p < 0.001) and NORM (p < 0.01) groups. Alarms were higher in all study groups compared to the NORM group. An algorithm integrating these structural and alarm parameters is proposed.ConclusionThis study demonstrated that Ly‐X, Ly‐Z, and Ly‐WZ lymphocyte parameters are useful for detecting morphological changes in lymphocytes; they provide useful information for the differential diagnosis of lymphocytosis, and this before the examination of the blood smear. An algorithm combining the WDF (parameters) and the WPC (alarms) makes it possible to decide whether or not to use a microscopic examination or flow cytometry immunophenotyping.

Publisher

Wiley

Subject

Biochemistry (medical),Clinical Biochemistry,Hematology,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3