Evaluation of effects of brackets and orthodontic wires on intraoral scans: A prospective in‐vivo study

Author:

Palone Mario1ORCID,Bellavia Marco1,Floris Matteo2,Rombolà Andrea1,Cremonini Francesca1,Albertini Paolo1ORCID,Lombardo Luca1

Affiliation:

1. Postgraduate School of Orthodontics University of Ferrara Ferrara Italy

2. Department of Biomedical Sciences University of Sassari Sassari Italy

Abstract

AbstractObjectiveTo evaluate any distortion produced by multibracket fixed orthodontic appliances on digital models obtained from intraoral scans (IOS), considering the presence of both brackets only and brackets/archwire combination.Setting/SampleThe IOS data of the arches of 20 patients (12 females and 8 males; mean age = 15.55 ± 2.84 years) were acquired using the CS3600 intraoral scanner (Carestream Dental, Atlanta, USA), without any appliances (model A), with vestibular brackets alone (model B) and then with brackets and orthodontic archwire fitted (model C).Materials and MethodsData were acquired between the months of January and October 2021 at the moment of indirect bonding phase. On each model, five intra‐arch linear measurements were obtained (inter‐canine, inter‐premolar 1 and 2, inter‐molar and arch depth), and after digital matching between model A and B (match 1) and A and C (match 2), the linear discrepancies were evaluated at 20 points (10 occlusal and 10 gingivolingual) previous identified on the reference model A. All measurements were performed using Geomagic Control X software (3D Systems, Morrisville, USA), and any dimensional variations and distortions were evaluated by the linear regression analysis and two‐sample t‐test (P ≤ .05).ResultsThe results show an almost perfect correlation between both models B and C and the reference model A, both as regards the intra‐arch linear measurements and the linear discrepancies found at the 20 identified points.ConclusionsMultibracket fixed orthodontic appliances do not produce any relevant distortions in digital models obtained via intraoral scanning. Therefore, the removal of archwire is not mandatory before IOS.

Publisher

Wiley

Subject

Otorhinolaryngology,Oral Surgery,Surgery,Orthodontics

Reference35 articles.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3