Affiliation:
1. Department of Urology All India Institute of Medical Sciences (AIIMS) Bhubaneswar India
Abstract
ObjectivesTo assess the efficacy of routine use of intraoperative ultrasonography (IOUS) in improving perioperative outcomes in patients undergoing IOUS‐guided laparoscopic nephrectomy (IOUS‐LN) and conventional laparoscopic nephrectomy (C‐LN).Patients and MethodsThis was a parallel‐arm, single‐blinded, randomised controlled trial (CTRI/2021/12/038906). All patients undergoing LN, either for benign or malignant causes, were included. Patients undergoing partial/cytoreductive nephrectomy, with venous thrombus were excluded. In the study arm, IOUS‐guided renal vascular assessment was performed after colon mobilisation and a standard LN was performed in the control arm. The primary outcome was intraoperative duration. The secondary outcomes were blood loss, need for open conversion, blood transfusion, perioperative complications, duration of Intensive Care Unit (ICU) stay and length of hospitalisation (LOH). The patients were followed for 3 months after surgery.ResultsA total of 104 patients were included, with 52 in each arm. Demographic characteristics were comparable in both arms. A significant reduction in the operative duration (mean [sd] 181.69 [40.8] vs 199.7 [41.8] min, P = 0.02) was seen in the IOUS‐LN group. The difference in blood loss showed no significant difference when compared between both groups (median [interquartile range] 84.55 [74–105.5] vs 99.95 [78.5–111] mL, P = 0.08). On subgroup analysis, the reduction in the operative duration was significant in patients who underwent laparoscopic simple nephrectomy (LSN; mean [sd] 194.4 [42.5] vs 221.2 [36.4] min, P = 0.01), whereas comparable operative durations were seen in patients undergoing laparoscopic radical nephrectomy (LRN; mean [sd] 168.96 [35.3] vs 178.3 [35.9] min, P = 0.34). Similar conversion rates were seen in both groups (P = 0.98) along with blood transfusions (P = 0.78). The LOH, ICU stay, and complications were similar in both groups. Significantly less blood loss (P = 0.03) was noted with IOUS in patients undergoing LSN. IOUS did not influence any outcomes in patients undergoing LRN.ConclusionIntraoperative ultrasonography significantly reduced the operative duration in LN, but with no significant reduction in the volume of blood loss. Significant reduction in intraoperative duration and blood loss was seen in patients who underwent LSN on subgroup analysis.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献