Report of the International Council for Standardization in Haematology working group for standardization of reticulocyte parameters

Author:

Obstfeld Amrom E.12ORCID,Davis Bruce H.3,Han Jin‐Yeong45ORCID,Urrechaga Eloisa6

Affiliation:

1. Department of Pathology & Laboratory Medicine Children's Hospital of Philadelphia Philadelphia Pennsylvania USA

2. Department of Pathology & Laboratory Medicine Perelman School of Medicine at the University of Pennsylvania Philadelphia Pennsylvania USA

3. 700 Trillium LN Clifton Maine USA

4. Department of Laboratory Medicine Dong‐A University College of Medicine Busan South Korea

5. Department of Laboratory Medicine Dong‐A University Hospital Busan South Korea

6. Biocruces Bizkaia Health Research Institute Barakaldo Spain

Abstract

AbstractIntroductionThe International Council for Standardization in Haematology convened a working group to assess and propose improvements upon the state of standardization and harmonization of reticulocyte parameters among commercial hematology analyzers.MethodsAn international group of laboratory hematologists prospectively collected and analyzed clinical samples using locally available IVD commercial hematology analyzers. Eight hundred and fifty‐five total samples were collected at 6 sites using 9 distinct analyzer types. Samples were assessed for reticulocyte percent (RET%), immature reticulocyte fraction (IRF), and reticulocyte hemoglobin content (RHC). Method comparison and regression statistics were calculated. These analyses were used to determine whether statistical recalibration offered a potential avenue for increasing comparability between these methods.ResultsWhile methods producing reticulocyte percent were the most comparable in this study, the state of harmonization for the IRF and RHC was reduced with pearson correlation coefficients ranging from 0.955 to 0.77 and 0.927 and 0.680, respectively. Nevertheless, use of parameters from the Passing Bablok regression substantially improved the comparability of the results. In addition, precision data was derived which also demonstrated substantial differences between analyzer systems.ConclusionWhile reticulocyte counting is correlated between the automated methods evaluated in this study, the current state of harmonization of other reticulocyte parameters is not as strong. A major challenge in moving this field forward is the need for commutable materials to facilitate comparisons between analyzers not co‐located. A potential alternate approach to improve the current state would be instrument re‐calibration. However, this is challenging both technically and due to national regulatory frameworks.

Publisher

Wiley

Subject

Biochemistry (medical),Clinical Biochemistry,Hematology,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Reticulocytes and Related Parameters in Clinical Practice;International Journal of Child Health and Nutrition;2024-03-25

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3