Abstract

AbstractObjectivesHematopoietic stem cell transplantation (HSCT) is a potentially curative treatment for various diseases. The measurement of CD34+ cells is crucial to schedule the peripheral blood stem cell collection and assess the engraftment potential of the apheresis product. The AQUIOS STEM system has been introduced as a novel application on the AQUIOS CL, a fully automated flow cytometer, for the enumeration of CD34+ hematopoietic progenitor cells (HPCs) in accordance with the The International Society for Hematotherapy and Graft Engineering guidelines. This study aimed to assess the potential of the novel AQUIOS STEM system versus currently used systems including the FACSCanto‐II and the FACS Lyric flow cytometer in a multicenter study.MethodsA total of 91 samples were used for the validation of the AQUOIS STEM system, including an analytical performance evaluation by means of assessing precision, sample stability, intersample carryover, and linearity and a method comparison with the present FACS systems in use to assess analytical and clinical decision agreement.ResultsResults showed excellent precision, with coefficient of variations <15% for dedicated quality control material and patient samples. There was no significant carry over. The fresh apheresis samples were stable when stored overnight at room temperature and at 4°C. Analytical comparison with the current systems demonstrated good correlation in peripheral blood, and minimal, clinically neglectable systematic and proportional bias in fresh apheresis products but a low correlation coefficient in cryopreserved products.ConclusionsThe STEM system on AQUIOS CL allows automated enumeration of CD34+ stem cells, demonstrating good analytical performance and promising overall outcomes in peripheral blood and fresh apheresis products.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3