Single implant retained overdentures: Evaluation of effect of implant length and diameter on stress distribution by finite element analysis

Author:

Eraslan Ravza1,Yagci Filiz1ORCID,Esim Emir2

Affiliation:

1. Department of Prosthodontics Erciyes University Faculty of Dentistry Kayseri Turkey

2. Mechatronics Engineering Department Erciyes University Faculty of Engineering Kayseri Turkey

Abstract

AbstractPurposeSingle implant retained mandibular overdenture treatment has been shown to be a minimally invasive, satisfactory, and cost‐effective option for edentulous individuals. However, the impact of implant diameter and length on stress distribution at the implant, bone, and other components in this treatment approach remains unclear. The purpose of this 3D finite element analysis was to evaluate the effect of implant length and diameter on equivalent von Mises stress and strain distribution in single implant retained overdentures at bone, implant, and prosthetic components.Materials and MethodsNine models were constructed according to implant lengths (L) (8, 10, 12 mm) and diameters (D) (3.3, 4.1, 4.8 mm). The implants were positioned axially, in the midline of the mandible. A 3D model of the edentulous mandible was created from a computed tomography image. A single implant, abutment with insert PEEK and a housing, acrylic denture, and Co‐Cr framework were modeled separately. In the ANSYS software program, occlusal loads were applied as 150 N, bilaterally vertical direction, or unilaterally oblique direction to the first molar. Minimum principal stress values were evaluated for bone and equivalent von Mises stress and strain values were evaluated for implant and prosthetic components.ResultsVon Mises stress values for vertical load increased at implant, housing, and insert PEEK for all groups when the length of the implant increased. When oblique load was applied, 3.3 mm diameter implant groups showed maximum von Mises stress values for implants, cortical bone, cancellous bone, and housing among all groups. A minimum stress level for implant was found in D4.1/L8 group. Regarding the insert PEEK, strain values were found to be higher as the diameter of the implant increased both for vertical and oblique loads. Cortical bone showed higher minimum principal stress values as compared to cancellous bone under both loading conditions.ConclusionsThe 3.3 mm diameter implant groups exhibited the highest von Mises stress and strain values for both loading conditions at the implant. The diameter of the implant had a greater impact on stress and strain levels at the implant site compared to length. For vertical loading, stress value increased at implant, housing, and PEEK when the length of the implant increased.

Publisher

Wiley

Subject

General Dentistry

Reference44 articles.

1. Global oral health of older people—Call for public health action;Petersen PE;Community Dent Health.,2010

2. Clinical morbidity and sequelae of treatment with complete dentures

3. The influence of clinical variables on patients' satisfaction with complete dentures

4. Use of a single implant to retain mandibular overdenture: A preliminary clinical trial of 13 cases

5. The McGill consensus statement on overdentures;Feine JS;Quintessence Int.,2003

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3