Comparison of blood ΒHBA measurement devices for diagnosis of subclinical pregnancy toxaemia in sheep: A field study

Author:

Turgut Ali Osman1ORCID,Koca Davut2ORCID,Ünver Ali3ORCID

Affiliation:

1. Department of Animal Science, Faculty of Veterinary Medicine Siirt University Siirt Turkey

2. Department of Obstetrics and Gynecology, Faculty of Veterinary Medicine Van Yuzuncu Yil University Van Turkey

3. Department of Obstetrics and Gynecology, Faculty of Veterinary Medicine Siirt University Siirt Turkey

Abstract

AbstractPregnancy toxaemia is a serious disease that occurs during the last trimester of pregnancy in sheep. Yet, in most cases, the disease may have a subclinical course. This study was aimed at comparing blood βHBA measurement devices for diagnosis of subclinical pregnancy toxaemia in late pregnant sheep. In the study, a total of 50 blood samples were collected from Romanov (n = 30) and cross‐bred Hamdani (n = 20) sheep. Blood βHBA levels were measured using TaiDoc TD‐4235 and CentriVet βHBA hand‐held meter. Randox βHBA (Ranbut) assay was used as a reference laboratory method to compare hand‐held meters. βHBA value of 0.8 mmol/L was set as the cut‐off value for diagnosis of subclinical pregnancy toxaemia. Statistical analyses were carried out using Minitab 21 and Jamovi software. In the study, the correlation of Randox‐TaiDoc TD‐4235 and Randox‐CentriVet was .822 (p < .001) and .728 (p < .001), respectively. Based on the Ranbut assay, nine ewes out of 50 were diagnosed with subclinical pregnancy toxaemia. Specificity (detection of healthy ewes) and sensitivity (detection of ewes with subclinical pregnancy toxaemia) for TaiDoc TD‐4235 and CentriVet hand‐held meters were 100%, 77.8%, and 100%, 66.7%, respectively. In the receiver operating characteristic (ROC) analysis, areas under the ROC curve (AUC) were 0.976 and 0.920 for TaiDoc and CentriVet, respectively. Bland–Altman analysis revealed a bias of 0.092 mmol/L for TaiDoc and a bias of 0.132 mmol/L for CentriVet. TaiDoc hand‐held meter shows a better correlation with the Randox Ranbut assay and greater sensitivity compared to the CentriVet hand‐held meter. In conclusion, both TaiDoc and CentriVet hand‐held meters can be securely used in the diagnosis of subclinical pregnancy toxaemia in sheep. For these reasons, subclinical pregnancy toxaemia and these devices will be evaluated within the scope of herd management programme in the sheep industry. It should also be taken into account that these conditions will affect the future fertility of the mother and offspring.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3