Analysis of spinal canal diameter in the placement of thoracic spinal cord stimulator paddle leads

Author:

Ragel Brian T.1ORCID,Riedman Tressa12,McGehee Matthew2,Raslan Ahmed M.3

Affiliation:

1. Division of Neurosurgery Rebound Orthopedics and Neurosurgery Portland Oregon USA

2. Division of Physiatry Rebound Orthopedics and Neurosurgery Portland Oregon USA

3. Department of Neurological Surgery Oregon Health and Science University Portland Oregon USA

Abstract

AbstractBackgroundNeurologic deficit is known as a rare complication of thoracic spinal cord stimulator (SCS) paddle lead implantation, but many believe its incidence after SCS paddle lead placement is under‐reported. It is possible that imaging characteristics may be used to help predict safe paddle lead placement.ObjectiveThis imaging study was undertaken to determine the minimum canal diameter required for safe paddle lead placement.MethodsPatients who underwent thoracic laminotomy for new SCS paddle lead placement from January 2018 to March 2023 were identified retrospectively. Preoperative thoracic canal diameter was measured in the sagittal plane perpendicular to the disc space from T5/6 to T11/12. These thoracic levels were chosen because they span the most common levels targeted for SCS placement. Patients with and without new neurologic deficits were compared using a Mann–Whitney U‐test.ResultsOf 185 patients initially identified, 180 had thoracic imaging available for review. One (0.5%) and 2 (1.1%) of 185 patients complained of permanent and transient neurologic deficit after thoracic SCS placement, respectively. Patients with neurologic deficits had average canal diameters of <11 mm. The average canal diameter of patients with and without neurologic deficits was 10.2 mm (range 6.1–12.9 mm) and 13.0 mm (range 5.9–20.2), respectively (p < 0.0001).ConclusionPostoperative neurologic deficit is an uncommon complication after thoracic laminotomy for SCS paddle lead placement. The authors recommend ensuring a starting thoracic canal diameter of at least 12 mm to accommodate a SCS paddle lead measuring 2 mm thick to ensure a final diameter of >10 mm. If canal diameter is <12 mm, aggressive undercutting of the lamina, a second laminotomy, or placement of smaller SCS wire leads should be considered.

Publisher

Wiley

Subject

Anesthesiology and Pain Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3