Resolution and penetration depth of reflection-mode time-domain near infrared optical tomography using a ToF SPAD camera

Author:

Jiang JingjingORCID,Ackermann Meret,Russomanno Emanuele,Di Costanzo Mata Aldo,Charbon Edoardo1,Wolf MartinORCID,Kalyanov AlexanderORCID

Affiliation:

1. EPFL

Abstract

In a turbid medium such as biological tissue, near-infrared optical tomography (NIROT) can image the oxygenation, a highly relevant clinical parameter. To be an efficient diagnostic tool, NIROT has to have high spatial resolution and depth sensitivity, fast acquisition time, and be easy to use. Since many tissues cannot be penetrated by near-infrared light, such tissue needs to be measured in reflection mode, i.e., where light emission and detection components are placed on the same side. Thanks to the recent advance in single-photon avalanche diode (SPAD) array technology, we have developed a compact reflection-mode time-domain (TD) NIROT system with a large number of channels, which is expected to substantially increase the resolution and depth sensitivity of the oxygenation images. The aim was to test this experimentally for our SPAD camera-empowered TD NIROT system. Experiments with one and two inclusions, i.e., optically dense spheres of 5mm radius, immersed in turbid liquid were conducted. The inclusions were placed at depths from 10mm to 30mm and moved across the field-of-view. In the two-inclusion experiment, two identical spheres were placed at a lateral distance of 8mm. We also compared short exposure times of 1s, suitable for dynamic processes, with a long exposure of 100s. Additionally, we imaged complex geometries inside the turbid medium, which represented structural elements of a biological object. The quality of the reconstructed images was quantified by the root mean squared error (RMSE), peak signal-to-noise ratio (PSNR), and dice similarity. The two small spheres were successfully resolved up to a depth of 30mm. We demonstrated robust image reconstruction even at 1s exposure. Furthermore, the complex geometries were also successfully reconstructed. The results demonstrated a groundbreaking level of enhanced performance of the NIROT system based on a SPAD camera.

Funder

Universität Zürich

National Council of Science and Technology

Innovationspool of the University Hospital Zurich

Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung

Publisher

Optica Publishing Group

Subject

Atomic and Molecular Physics, and Optics,Biotechnology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. SPAD-sensor-based near-infrared imaging and dynamic phantom platform system;Optics in Health Care and Biomedical Optics XIII;2023-11-27

2. Potential for remote TD-NIRS imaging using a TCSPC camera;Measurement Science and Technology;2023-05-22

3. Image Reconstruction Using Deep Learning for Near-Infrared Optical Tomography: Generalization Assessment;Advances in Experimental Medicine and Biology;2023