Patterns of quality assurance and treatment planning for stereotactic body radiation therapy in India – A survey

Author:

Sharma Smriti12,Upreti Ritu Raj23,Kinhikar Rajesh A.23,Sahani G.1,Dash Sharma P. K.1

Affiliation:

1. Radiological Safety Division, Atomic Energy Regulatory Board, Anushaktinagar, Mumbai, Maharashtra, India

2. Homi Bhabha National Institute, Anushaktinagar, Mumbai, Maharashtra, India

3. Department of Medical Physics, Tata Memorial Centre, Mumbai, Maharashtra, India

Abstract

ABSTRACT Aim: The use of stereotactic body radiation therapy (SBRT) is an increasing trend in the country. The aim of this study is to gain knowledge on patterns of quality assurance (QA) and treatment planning (TP) aspects with respect to SBRT. Materials and Methods: A questionnaire with multiple choice was designed to determine practices of SBRT covering areas such as years of experience, type of linear accelerator, tumor-motion strategies, calculation algorithm used in the TP system (TPS), the protocol used for small field dosimetry, the detector used for small field dosimetry and QA, respiratory management during delivery. The survey was sent to all radiotherapy institutes in the country having a minimum of one linear accelerator, and responses were analyzed. Results: From June 2022 to December 2022, 265 responses to the SBRT survey were received with response rate as 60.4%. The most common reason for not adopting SBRT was reported as a lack of capability of treatment machines to deliver SBRT (61.6%). Lung (81.1%) was the most practiced site. The most common delivery unit was a conventional linear accelerator (83%); 6 MV FFF (85.7%) was mostly used energy; volumetric-modulated arc radiotherapy (VMAT) (91.5%) was mostly used delivery technique; most of the equipment (more than 91.5%) used multileaf collimator (MLC) leaf width ≤5 mm. The most popular methods used for motion strategies during computed tomography (CT) were motion-encompassing and breath-hold techniques used by 65 (62.5%) and 62 (59.6%) respondents, respectively. The most popular method used for respiratory management during delivery was breath-hold by 55 (52.4%) respondents. Most TPS are equipped with either Type-C or Type-B algorithms. Heterogeneity was observed in the QA protocol and acceptance criteria for analysis of patient-specific QA. Conclusion: The survey resulted in heterogeneity in QA and TP aspects among users of SBRT and demands for harmonizing the dosimetric aspects of SBRT in the country.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3