Author:
Bakthavatchalam Balakrishnan,Ranjani Muthukrishnan Sudharshana,Amudhalakshmi Krishnan
Abstract
Aim:
This study aims to compare the cleaning efficacy of root canal walls using two rotary single file systems: self-adjusting file (SAF) and WaveOne (WO).
Materials and Methods:
Forty extracted human premolars with similar range of canal curvature were selected, decoronated, working length determined and roots were divided into two groups of 20 samples each: Group I - SAF and Group II - WO. All root canals were irrigated with 3% sodium hypochlorite (NaOCl) and 17% ethylenediaminetetraacetic acid (EDTA). The roots were sectioned longitudinally and subjected to scanning electron microscopic examination. The amount of debris and smear layer was evaluated using five score index at coronal, middle and apical third levels. Statistical analysis was performed using the Chi-square test and significance was set at a P < 0.05.
Results:
Statistically significant difference was observed between the groups in cleaning the apical third. Group I (SAF) showed better canal cleanliness compared to Group II (WO) in the apical third.
Conclusion:
Within the limitations of this study, SAF in combination with 3% NaOCl and 17% EDTA irrigating solution had significantly better cleaning efficacy in the apical third of root canals when compared to WO rotary file system.
Subject
Periodontics,Oral Surgery,Orthodontics
Reference35 articles.
1. Current challenges and concepts in the preparation of root canal systems: A review;Peters;J Endod,2004
2. The self-adjusting file (SAF). Part 1: Respecting the root canal anatomy – A new concept of endodontic files and its implementation;Metzger;J Endod,2010
3. From files to SAF: 3D endodontic treatment is possible at last;Metzger;Alpha Omegan,2011
4. The Self-adjusting File system;Metzger;ENDO (Lond Eng,2013
5. The WaveOne single-file reciprocating system;Webber;Roots,2011