Impact of soft and rigid gas-permeable contact lenses on visual performance in mesopic conditions

Author:

Krolo Iva12,Bećirević Aida Kasumović13,Radman Ivana1,Sabol Ivan4,Ravlić Maja Malenica1,Ratković Mirko5,Belovari Mirna6

Affiliation:

1. University Department of Ophthalmology, University Hospital Center Sestre Milosrdnice, Zagreb, Croatia

2. Department of Ophthalmology, Antwerp University Hospital, Edegem, Belgium

3. Eye Polyclinic Dr. Sefić, Sarajevo, Bosnia and Herzegovina

4. Ruđer Bošković Institute, Zagreb, Croatia

5. Department of Ophthalmology, NU Hospital Group, Uddevalla Hospital, Uddevalla, Sweden

6. Optical Express, Hainault House, Tallaght, Dublin, Ireland

Abstract

Context: Evaluation of visual quality in soft and rigid gas-permeable contact lens wearers, with an emphasis on twilight vision. Purpose: To assess the visual acuity and visual performance at dusk before and after soft and rigid gas-permeable contact lens (CL) correction in healthy subjects. Settings and Design: This prospective study was conducted in a tertiary eye-care center. Methods: Sixty eyes corrected with soft contact lenses (SCLs) and 30 eyes with rigid gas-permeable contact lenses (RGPCLs) were enrolled in this study. Patients underwent corrected distance visual acuity with spectacles (CDVAs), corrected distance visual acuity with contact lenses (CDVAcl), and twilight vision (TV) testing (Vista Vision Far-Pola, DMD MedTech charts). Parameters were evaluated before and after the CL fitting and repeated 3 months after the baseline visit. Statistical Analysis Used: MedCalc for Windows, version 11.4 (MedCalc Software, Ostend, Belgium). Results: Rigid gas-permeable CL wear showed significant improvement in CDVAcl compared to wearing spectacles on both visits (P = 0.0039 and P = 0.0003, respectively). TV with CLs was significantly better in both groups compared to the TV with spectacles at the baseline visit (P = 0.0011 in SCL group; P = 0.0001 in RGPCL group), and at the follow-up visit, this significance was proven for the RGPCL group (P = 0.001). Also, spectacle TV showed a significant improvement on the follow-up visit (P = 0.0022 in SCL group; P = 0.0269 in RGPCL group). Conclusion: Contact lens wear improves visual performance compared to spectacles. TV results showed superiority of CLs compared to the spectacles, without a statistical difference regarding the CL type.

Publisher

Medknow

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3