The effect of different pressures of pneumoperitoneum on the optic nerve sheath diameter – A prospective study

Author:

Ponduru Supraja1,Nanda Ananya1,Pakhare Vandana Patilbuwa1,Gopinath Ramchandran1,Sangineni Kalyani Suryadhanalakshmi2,Priyanka R. Devi Sai1

Affiliation:

1. Department of Anaesthesia, ESIC Medical College and Hospital, Hyderabad, India

2. Department of Anaesthesia, AIIMS, Bibinagar, Telangana, India

Abstract

Abstract Background and Aims: Increased intra-abdominal pressure (IAP) and carbon dioxide gas during pneumoperitoneum leads to various systemic changes involving cardiovascular, respiratory, and cerebral physiology. In our study, we aimed to investigate the effect of standard (13–15 mmHg) and low (6–8 mmHg) pressure pneumoperitoneum on optic nerve sheath diameter (ONSD) using ultrasound, which is a reflection of intracranial pressure (ICP). Patient hemodynamics, surgery duration and surgeons’ comfort, and ease of performing surgery at low-pressure pneumoperitoneum were studied as secondary objectives. Materials and Methods: In this prospective double-blind randomized study, 75 patients of the American Society of Anesthesiologists physical status grades I and II, of both genders undergoing elective laparoscopic surgery, were allocated into two groups – S (standard IAP 13–15 mmHg) and L (low IAP 6–8 mmHg). ONSD acquired at different time points: before induction of anesthesia (T1), 5 min after intubation (T2), 5 min after the creation of pneumoperitoneum (T3), 5 min before desufflation (T4), and 5 min before extubation (T5). ONSD of 5 mm is taken as the cutoff value to correlate raised ICP. Continuous variables were analyzed by the Student’s t-test, and categorical data were assessed by the Chi-square test. Results: There was a significant increase in ONSD with insufflation in both the groups; however, T3 is higher than the cutoff value (>5 mm) in Group S. The ONSD values at T1 (baseline) and at T2 (after intubation) were comparable between the groups, with P = 0.1855 and P = 0.8988, respectively. With pneumoperitoneum, the increase in ONSD (T3) is significantly higher in Group S than in Group L with P = 0.0022, attributing to the high IAP in Group S. Conclusion: Laparoscopic surgery with low-pressure pneumoperitoneum can be a safe approach, particularly in individuals at risk of raised ICP.

Publisher

Medknow

Subject

General Earth and Planetary Sciences,General Medicine

Reference17 articles.

1. Secrets of safe laparoscopic surgery:Anaesthetic and surgical considerations;Srivastava;J Minim Access Surg,2010

2. The effect of different pressures of pneumoperitoneum on the dimensions of internal jugular vein –A prospective double-blind, randomised study;Ponduru;Indian J Anaesth,2022

3. Goal-directed fluid therapy enhances gastrointestinal recovery after laparoscopic surgery:A systematic review and meta-analysis;Virág;J Pers Med,2022

4. Comparison of optic nerve sheath diameter (ONSD) in low-pressure versus normal pressure pneumoperitoneum in laparoscopic cholecystectomy:A randomized clinical study;Salimi;Med J Islam Repub Iran,2022

5. Effect of pneumoperitoneum and patient positioning on intracranial pressures during laparoscopy:A prospective comparative study;Sahay;J Minim Invasive Gynecol,2018

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3