Assessment of the impact of XP-Endo Finisher file on push-out bond strength of various endodontic sealers

Author:

Mohite Pramod1,Gupta Divya1,Gupta Ruchika2,Kamat Sharad3,Shaw Amar Kumar4

Affiliation:

1. Department of Conservative Dentistry and Endodontics, Vasantdada Patil Dental College, India

2. Department of Conservative Dentistry and Endodontics, D. Y. Patil Dental School, Pune, India

3. Department of Conservative Dentistry and Endodontics, Bharati Vidyapeeth (Deemed to be University) Pune, Dental College and Hospital, Sangli, Maharashtra, India

4. Department of Public Health Dentistry, Bharati Vidyapeeth (Deemed to be University) Dental College and Hospital, Pune, Maharashtra, India

Abstract

Abstract Background: An endodontic treatment is considered a success after thorough chemomechanical debridement coupled with obturating root canals in a concrete way thereby providing hermetic seal. Gutta-percha being nonadherent necessitates use of a sealer to achieve hermetic seal. Adequate adhesion of root canal sealer with gutta-percha core and radicular dentin ensures lack of apical leakage. Materials and Methods: Sixty extracted mandibular premolars with single root canal decoronated at cementoenamel junction were selected and randomly allocated to two groups (n = 30). Samples in Group 1 were prepared with BT Race file, while Group 2 samples were prepared with BT Race alongwith XP Endo file. Absorbent paper points were used for canal drying and samples were randomly divided into six subgroups. In Subgroup I, obturation was done with bio-ceramic (BC) sealer (Endosequence BC) and BC gutta-percha. In Subgroup II, resin-based (AH plus) sealer and gutta-percha were used. In Subgroup III, calcium hydroxide-based (Sealapex) sealer and gutta-percha were used. Sectioning of root samples was done perpendicularly into coronal, middle, and apical segments of 3 mm each. A universal testing machine was used for sample testing, in which push-out bond strength corresponded to the highest value obtained. Stereomicroscopic (×20) study of the samples determined the failure mode at dentin/sealer/main cone interface. Statistical Analysis: Analysis of variance and post hoc Tukey’s tests were used for data analysis. Results: Endosequence BC with XP-Endo files showed the highest mean push-out bond strength (16.31 MPa), whereas Sealapex without XP-Endo file had the lowest values (12.76 MPa). Mixed failure of adhesive and cohesive mode was observed for most samples. Conclusion: Adjunctive irrigation agitation technique utilizing XP-Endo Finisher facilitates biofilm eradication from difficult niches in root canals, thereby improving adhesion of sealer and subsequently the sealer bond strength.

Publisher

Medknow

Reference26 articles.

1. Push-out bond strengths of the dentine-sealer interface with and without a main cone;Jainaen;Int Endod J,2007

2. Comparison of the tensile bond strength of four root canal sealers;Khedmat;J Dent,2006

3. Push-out bond strength of calcium hydroxide and mineral trioxide aggregate based sealers to root canal dentin;Souza;Revista Odonto Ciencia,2012

4. Micro push-out bond strength and bioactivity analysis of a bioceramic root canal sealer;Carvalho;Iran Endod J,2017

5. Evaluation of Er: YAG laser and EDTAC on dentin adhesion of six endodontic sealers;Pécora;Braz Dent J,2001

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3