Impact of Respiratory-gated 4D PET/CT Scan for Motion Correction in Characterizing Lesions Adjacent to the Diaphragm – A Cross-sectional Study at a Tertiary Care Institute

Author:

Patro Sai Sradha P.1,Aland Parag2,James Vivek Mathew3,Lele Vikram4

Affiliation:

1. Department of Nuclear Medicine, All India Institute of Medical Sciences, Bhubaneswar, Odisha, India

2. Department of Nuclear Medicine, Infinity Medical Centre, Mumbai, Maharashtra, India

3. Department of Nuclear Medicine, Government Medical College, Thiruvananthapuram, Kerala, India

4. Department of Nuclear Medicine and Positron Emission Tomography-Computed Tomography, Jaslok Hospital and Research Centre, Mumbai, Maharashtra, India

Abstract

Abstract Purpose: The blur introduced by breathing motion degrades the diagnostic accuracy of whole-body F-18 fluorodeoxyglucose positron emission tomography–computed tomography (18F-FDG PET-CT) in lesions adjacent to the diaphragm by increasing the apparent size and by decreasing their metabolic activity. This study aims to evaluate the efficacy of motion correction by four-dimensional phase-based respiratory-gated (RG) 18F-FDG PET-CT in improving metabolic parameters of lesions adjacent to the diaphragm (especially in the lungs or liver). Materials and Methods: Eighteen patients with known lung or liver lesions underwent conventional 18F-FDG PET-CT and respiratory-gated PET-CT acquisition of the desired region using a pressure-sensing, phase-based respiratory-gating system. Maximum standardized uptake value (SUVmax), metabolic tumor volume (MTV), and total lesion glycolysis (TLG) were obtained for these lesions from gated and nongated PET-CT images for analysis. Furthermore, a visual analysis of lesions was done. Statistics: Statistical significance of the RG image parameters was assessed by the two-tailed paired Student’s t test and confirmed with the robust nonparametric Wilcoxon’s signed-rank test (two-tailed asymptotic). Results: There was an overall significant increase in SUVmax (P 0.001) in all gating methods with a percentage increase maximum of about 18.13%. On gating methods, MTV decreased significantly (P = 0.001) than that of nongating method (maximum reduction of about 32.9%). There was a significant difference (P = 0.02) in TLG between gated and nongated methods. Conclusion: Motion correction with phase-based respiratory gating improves the diagnostic value of 18F-FDG PET-CT imaging for lung and liver lesions by more accurate delineation of the lesion volume and quantitation of SUV and can thus impact staging, diagnosis as well as management in selected patients.

Publisher

Medknow

Reference27 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3