Comparison of the Bone-Anchored Pendulum Appliance and the Bone-Anchored Intraoral Bodily Molar Distalizer: An Original Research

Author:

Patowary John1,Kumar Pranay2,Priya C V Padma3,Kanwal Bushra4,Kauser Afreen5,Chacko Prince K.6

Affiliation:

1. Department of Orthodontics and Dentofacial Orthopaedics, Regional Dental College, Bhangagarh, Guwahati, Assam, India

2. Department of Orthodontics and Dentofacial Orthopedics, Maharaja Ganga Singh Dental College and Research Centre, Ganganagar, Rajasthan, India

3. Department of Orthodontics and Dentofacial Orthopedics, Vishnu Dental College, Bhimavaram, Andhra Pradesh, India

4. Specialist Orthodontist, Rawa Almas Splendid Diamond Clinic, Al Baha, Saudi Arabia

5. Department of Orthodontics and Dentofacial Orthopeadics, College of Dental Sciences, Davangere, Karnataka, India

6. Department of Orthodontics and Dentofacial Orthopedics, Educare Institute of Dental Sciences, Chattiparambu, Malappuram, Kerala, India

Abstract

ABSTRACT Introduction: With the advent of mini-implants, Class II correction has become routine. The study’s goal was to compare the “Bone-Anchored Pendulum Appliance (BAPA)” to the “Bone-Anchored Intraoral Bodily Molar Distalizer (BAIBMD)” in terms of clinical efficacy. Materials and Procedures: Five boys and five girls were among the 10 patients in this split-mouth trial who had to have their molars distalized. On one side, BAPA Construction, and on the other, BAIBMD was piloted. A titanium mini-screw was used to secure both appliances to the bone since this was a spilled-mouth technique. The first molar bands to apply 200 g of force were used for both devices, as with all the other components that were similar for both appliances. For both sides, the nature, duration, and rate of tooth movement were compared. Using the Wilcoxon signed-rank test, descriptive statistics for several parameters were examined. Results: Distalization was accomplished on both sides with clinical success. The rate of distalization did not show any significant variation. Less time was needed for distalization with BAPA, as evidenced by the statistically substantial variances in treatment duration between the two groups. Molar tipping was noticed in BAPA, and it was statistically significant. Conclusion: While the pace of distalization was equal for both appliances, BAIBMD required more time than BAPA but resulted in a distal tooth movement that was mostly translatory in nature.

Publisher

Medknow

Subject

General Pharmacology, Toxicology and Pharmaceutics,General Biochemistry, Genetics and Molecular Biology,Bioengineering,General Pharmacology, Toxicology and Pharmaceutics,General Biochemistry, Genetics and Molecular Biology,Bioengineering

Reference18 articles.

1. The pendulum appliance for Class II non-compliance therapy;Hilgers;J Clin Orthod,1992

2. A new approach in maxillary molar distalization:Intraoral bodily molar distalizer;Keles;Am J Orthod Dentofacial Orthop,2000

3. Mini-implant for orthodontic anchorage;Konomi;J Clin Orthod,1997

4. Maxillary molar distalization with a bone-anchored pendulum appliance;Kircelli;Angle Orthod,2006

5. Distalization of maxillary molars with the bone-supported-pendulum:A clinical study;Escobar;Am J Orthod Dentofacial Orthop,2007

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3