Affiliation:
1. Department of Radiology, Christian Medical College, Vellore, Tamil Nadu, India
Abstract
Objective:
Radiation-protective aprons are commonly used by interventionists to protect against the harmful effects of ionizing radiation. Choice of appropriate aprons with respect to lead equivalence and weight is necessary for effective protection and reduced physical strain. This study evaluates the knowledge and practice of using radiation-protective aprons by interventionists.
Materials and Methods:
Ninety-one interventional radiologists who attended an annual interventional conference were provided with a questionnaire which included age, years of experience, area of expertise, type and weight of apron used, and physical strain caused due to the use of apron.
Results:
About 14.3% of the interventionists practiced in an angiographic suite for less than an hour a day, 45% for 2–4 h, 21% for 4–6 h, 10% for 6–10 h, and the rest above 10 h/day. About 68% of the interventionists wore 0.5 mm lead-equivalent (Pbeq) aprons; 15.4% with 0.25 mm Pbeq; about 5.5% with 0.35 mm Pbeq aprons, and the remaining were not aware of the lead equivalence. About 47% reported that they had body aches due to wearing single-sided aprons. Interventionists working more than 10 h/day wearing single-sided lead apron predominantly complained of shoulder pain and back pain.
Conclusion:
A large fraction of interventionists reported that they had physical strain. It is suggestive for interventionists to wear correct fit and light-weight aprons with appropriate lead equivalence.
Subject
Radiology, Nuclear Medicine and imaging
Reference15 articles.
1. Lightweight aprons for protection against scattered radiation during fluoroscopy;Hubbert;AJR Am J Roentgenol,1993
2. Institute of Physics and Engineering in Medicine. Medical and Dental Guidance Notes: A Good Practice Guide on all Aspects of Ionising Radiation Protection in the Clinical Environment,2002
3. Pregnancy and women radiologists;Wagner;Radiology,1982
4. Minimizing occupational exposure;Shymko;Radiol Technol,1998
5. Radiation exposure to children during coil occlusion of the patent ductus arteriosus;Moore;Catheter Cardiovasc Interv,1999
Cited by
25 articles.