Volume, conductivity, and scatter parameters of leukocytes as early markers of sepsis and treatment response

Author:

Arora Parul1,Gupta Praveen Kumar2,Lingaiah Raghavendra1,Mukhopadhyay Asok Kumar1

Affiliation:

1. Department of Laboratory Medicine, All India Institute of Medical Sciences, New Delhi, India

2. Department of Laboratory Medicine, Primus Super Speciality Hospital, New Delhi, India

Abstract

Abstract INTRODUCTION: Morphologic changes in the size and granularity of leukocytes seen in sepsis could be measured using the volume, conductivity, and scatter (VCS parameters) from the automated hematology analyzers. The objective of this study is to find the clinical usefulness of VCS parameters as possible indicators of sepsis and to determine the effect of treatment on these parameters. METHODS: This observational study was conducted in a tertiary level hospital in India. Hemogram and VCS parameters obtained from LH 750 (Beckman coulter, Fullerton, CA) from 134 proven blood culture-positive cases of sepsis were reviewed on the day of culture positivity (day 0), day 3, and day 7 were analyzed and compared with those of samples from otherwise healthy 100 participants. Statistical analysis of data was done, and cutoff value was established using receiver-operator characteristic curve. RESULTS: Out of 134 culture-positive cases, 55.2% (n = 74) Gram-negative and 44.8% (n = 60) Gram-positive bacteria were isolated. The mean neutrophil volume (MNV) and mean monocyte volume (MMV) were higher in the sepsis group compared to that of the control group (165.43 ± 18.21 vs. 140.59 ± 7.6, P = 0.001 for MNV and 179.8 ± 14.16 vs. 164.54 ± 9.6, P = 0.001 for MMV). A significant decrease in MNV and MMV was observed with the initiation of the treatment. Significant changes in scatter and conductivity parameters were also noticed. A cutoff value of 150.2 for MNV gave a sensitivity and specificity of 79.1% and 95%, respectively, with an area under the curve (AUC) of 92.3%. With a cutoff of 168.3, MMV had a sensitivity of 80.6% and specificity of 77.5%, AUC of 83%. CONCLUSION: VCS parameters such as MNV and MMV can be easily obtained by an automated hematology analyzer and could be used for early detection and therapeutic response in sepsis.

Publisher

Georg Thieme Verlag KG

Reference23 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3