Abstract

Background The implantation of rotary blood pumps as ventricular assist devices (VADs) has become a viable therapy for quite a number of patients with end-stage heart failure. However, these rotary blood pumps cause adverse events that are related to blood trauma. It is currently believed that turbulence in the pump flow plays a significant role. But turbulence has not been measured to date because there is no optical access to the flow space in rotary blood pumps because of their opaque casings. Methods This difficulty is overcome with a scaled-up model of the HeartMate II (HM II) rotary blood pump with a transparent acrylic housing. A 2-component laser Doppler velocimetry (LDV) system was used for the measurement of time resolved velocity profiles and velocity spectra upstream and downstream of the rotor blades. Observing similarity laws, the speed and pump head were adjusted to correspond closely to the design point of the original pump – 10,600 rpm speed and 80 mmHg pressure head. A model fluid consisting of a water-glycerol mixture was used. Results The measured velocity spectra were scalable by the Kolmogorov length and the Kolmogorov length was estimated to be between 14 and 24 μm at original scale, thus being about 1.5 to 3 times the size of a red blood cell. Conclusions It can be concluded that turbulence is indeed present in the investigated blood pump and that it can be described by Kolmogorov's theory of turbulence. The size of the smallest vortices compares well to the turbulence length scales as found in prosthetic heart valves, for example.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3