Studying the Flow Dynamics in an Aortic Endograft with Crossed-limbs

Author:

Georgakarakos Efstratios1,Xenakis Antonios2,Manopoulos Christos2,Georgiadis George S.1,Argyriou Christos1,Tsangaris Sokrates2,Lazarides Miltos K.1

Affiliation:

1. Department of Vascular Surgery, Democritus Medical School, University Hospital of Alexandroupolis, Alexandroupolis - Greece

2. Fluids Section, School of Mechanical Engineering, National Technical University of Athens, Athens - Greece

Abstract

Purpose To evaluate the flow phenomena within an aortic endograft with crossed-limbs, comparing to an endograft with the ordinary limb bifurcation. Methods An endograft model with crossed-limbs was computationally reconstructed based on Computed Tomography patient-specific data, using commercially available software. Accordingly, its analogue model was reconstructed in the ordinary fashion (ordinary bifurcation). Computational fluid dynamics analysis was performed to determine and compare the flow fields, velocity profiles, pressure and shear stress distribution throughout the different parts of both endograft configurations, in different phases of the cardiac cycle. Results The flow patterns between the “Ballerina” and the classic endograft were similar, with flow disturbance near the inlet zone at late diastole and smooth flow patterns during the systolic phase. Both configurations presented similar pressure distribution patterns throughout the cardiac cycle. The highest and lowest pressures were demonstrated in the inlet-main body area and the iliac limbs, respectively. Marked differences were observed in the velocity profiles of the proximal limb segments between the two configurations, mostly in the peak- and end-systolic phase. The regions of lower velocities correlated well to low shear values. Differences in the shear stress distribution were noted between the two configurations in the systolic and, predominantly, in the diastolic phase. Conclusions There are differences in the velocity profiles and shear distribution between the limbs of the two endograft configurations. The pathophysiologic implication of our findings and their possible association with clinical events, such as thrombus apposition, deserves further investigation.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3