Histologic Evaluation of in vivo Femtosecond Laser–Generated Capsulotomies Reveals a Potential Cause for Radial Capsular Tears

Author:

Schultz Tim1,Joachim Stephanie C.2,Tischoff Iris3,Dick H. Burkhard1

Affiliation:

1. Institute for Vision Science, Ruhr University Eye Hospital, Bochum - Germany

2. Experimental Eye Research Institute, Ruhr University Eye Hospital, Bochum - Germany

3. Institute of Pathology, Ruhr University, Bochum - Germany

Abstract

Purpose To compare histologically the size and appearance of capsule disks after femtosecond laser–assisted cataract surgery and conventional cataract surgery. Methods In 100 eyes of 100 patients with visually significant cataracts, a femtosecond laser capsulotomy or a capsulorhexis with an aimed diameter of 5.0 mm was performed by one experienced surgeon. The diameter, area, circularity, and cut quality was histologically examined with light microscopy and scanning electron microscopy. Results The mean diameter of the manual and the femtosecond laser capsule disk group were not statistically significantly different (manual 4.91 ± 0.34; femtosecond: 4.93 ± 0.03; p = 0.58). The mean area of the capsule disks was 18.85 ± 2.69 mm2 in the manual and 19.03 ± 0.26 mm2 in the femtosecond group (p = 0.64). The capsules of the femtosecond group (0.95 ± 0.02) were significantly more circular than the ones of the manual group (0.81 ± 0.07; p<0.0001). The femtosecond laser capsule disks displayed a more saw blade–like structure created through the single laser spots. The histologic examination combined with prospective video analysis revealed respiratory movement of the eye during the capsulotomy as a potential risk factor for redial tears. Conclusions Femtosecond laser can perform a capsulotomy with high reliability. In comparison to a highly experienced cataract surgeon, the achieved results in size are similar. In terms of circularity, the femtosecond laser was superior the manual procedure. Better refractive outcomes based on a 360°-degree optic overlap seem to be possible, especially for less experienced surgeons.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

Cited by 28 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3