Safety and efficacy of combined micropuncture and shallow angle femoral artery access for neurovascular angiography

Author:

Bourgeois Austin C.1,Kolze Chris T.1,Guimaraes Marcelo S.2,Pasciak Alexander S.13,Ferrell Andrew S.13,Bradley Yong13,Kvamme Peter13

Affiliation:

1. University of Tennessee Graduate School of Medical Education, Knoxville, TN - USA

2. Department of Radiology, Medical University of South Carolina, Charleston, SC - USA

3. University of Tennessee Medical Center, Knoxville, TN - USA

Abstract

Introduction The AXERA 2 low-angle vascular access device utilizes a dual arteriotomy mechanism in which the standard access tract is compressed by a vascular sheath inserted over the second, low-angle tract. It is unknown whether this device could be effectively used with 21-gauge micropuncture access, as the micropuncture introducer makes a larger arteriotomy than the 19-gauge needle provided with the AXERA 2 system. Materials and Methods A retrospective review was performed on 189 patients who underwent common femoral artery access for diagnostic cerebrovascular angiography using either combined micropuncture and AXERA 2 access or standard access with manual pressure hemostasis. Demographic and procedural data were reviewed along with complications related to vascular access and times to bed elevation, ambulation and discharge. Results Combined micropuncture and AXERA 2 access was performed on 110 patients and 79 patients had standard access. The AXERA device was successfully used in 91.8% of the cases. Demographic data, anticoagulant use and sheath sizes were similar between both subsets. Use of the AXERA 2 was associated with two bleeding complications (1.8%) compared with 10 (12.7%) with manual pressure hemostasis alone. Institution-specific protocol allowed shorter mean manual compression time, as well as shorter times to ambulation and discharge with the AXERA 2. Conclusions Use of the AXERA 2 device with micropuncture access did not infer increased bleeding risk than standard arterial access in this patient series. The considerable incidence of device use failures suggests a learning curve associated with its use.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Diagnostic Value of CT Value of Arterial Angiography in Femoral Artery Obstructive Disease;Journal of Medical Imaging and Health Informatics;2020-04-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com