Evaluation of the Correct Position of Peripherally Inserted Central Catheters: Anatomical Landmark vs. Electrocardiographic Technique

Author:

Baldinelli Francesco1,Capozzoli Giuseppe1,Pedrazzoli Roberta1,Marzano Natascia2

Affiliation:

1. Department of Anesthesiology, Central Hospital of Bolzano, Bolzano - Italy

2. Department of Oncology, Central Hospital of Bolzano, Bolzano - Italy

Abstract

Purpose The purpose of this study is to verify as early as possible the correct positioning of the peripherally inserted central catheter (PICC) tip in order to reduce complications due to possible malpositioning. The ECG-guided technique proved to be reliable, easy to carry out, straightforward, low-cost and allows us to recognize an incorrect or a suboptimal positioning throughout the procedure. The purpose of this study is to compare two methods used during the PICC insertion so as to prevent catheter malpositioning; the first study estimates the catheter length by the landmark method (based on cutaneous anatomical landmarks, CALs) with the addition of the postprocedural verification of tip location by chest X-Ray (CxR), whereas the second method of intraprocedural tip location is based on the observation of the morphological variations of the P wave (ECG-guided technique) with the addition of the postprocedural verification by CxR. Methods From 2010 to 2012, 90 PICCs were positioned, 48 using the anatomical landmarks and 42 using the ECG technique. Results Twenty-five percent of the catheters positioned with the anatomical landmark technique did not reach the correct position of the tip in SVC; of these, 6.25% were placed in an aberrant position and others in a suboptimal position. Of the 42 PICCs positioned with the ECG technique, only in three cases (equal to 7.14%), a suboptimal position of the tip was observed, whereas there was no case of aberrant positioning. Conclusions The ECG technique represents an accurate, low-cost and safe technique to verify the correct positioning of the tip. The use of the ECG allowed a more correct positioning in terms of catheter tip-carina distance and catheter tip-tracheobronchial angle, and in no patient was it necessary to place a catheter again.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3